Page 111 of 401
10.10.2Syntax
Type Syntax Response Example
Set ATS2=<value> OK ATS2=43
OK
Read ATS2? <value>
OK
043
OK
10.10.3Defined values
Parameter Type Description
<value> Number Range 1 to 255. The answer to the read command is in "xxx" format. The default and
the factory-programmed value is 43 (ASCII '+').
10.10.4Notes
SARA-R4 / SARA-N4
The command has no effect.
10.11Command line termination character S3
S3
Modules All products
Syntax PIN required Settings saved Can be aborted Response time Error referenceAttributes
partial Yes No No - +CME Error
10.11.1Description
Sets a value representing the decimal IRA5 value of the character recognized by the DCE from the DTE,
to terminate the incoming command line. It is also generated by the DCE as part of the header, trailer and
terminator for result codes and information text, along with the S4 setting.
10.11.2Syntax
Type Syntax Response Example
Set ATS3=<value> OK ATS3=13
OK
Read ATS3? <value>
OK
013
OK
10.11.3Defined values
Parameter Type Description
<value> Number Range 0 to 127. The answer to the read command is in "xxx" format. The default and
the factory-programmed value is 13 (ASCII carriage return (CR, IRA5 0/13)).
10.12Response formatting character S4
S4
Modules All products
Syntax PIN required Settings saved Can be aborted Response time Error referenceAttributes
partial Yes No No - +CME Error
10.12.1Description
Sets a value representing the decimal IRA5 value of the character generated by the DCE as part of the header,
trailer and terminator for result codes and information text, along with the S3 setting.