Parameter Type Description
0: the DCE ignores circuit 108/2
1 (default value and factory-programmed value): upon an ON-to-OFF transition of
circuit 108/2, the DCE enters command mode and issues the final result code
2: upon an ON-to-OFF transition of circuit 108/2, the DCE performs an orderly
cleardown of the call. The automatic answer is disabled while circuit 108/2 remains
OFF
10.3.4Notes
The ON/OFF DTR transition in direct link forces the DCE into command mode. In case of AT&D0 the DTR
transition is ignored, also in direct link.
The escape sequence for the PSD data mode with a L2 protocol different from the PPP is not ~+++, and
it could be not supported. For more information, see the S2 notes.
10.4DSR override &S
&S
Modules All products
Syntax PIN required Settings saved Can be aborted Response time Error referenceAttributes
full No No No - +CME Error
10.4.1Description
Selects how the module will control RS232 circuit 107 - Data Set Ready (DSR).
10.4.2Syntax
Type Syntax Response Example
Action AT&S[<value>] OK
10.4.3Defined values
Parameter Type Description
<value> Number
0: sets the DSR line to ON
1 (default value and factory-programmed value): sets the DSR line to ON in data
mode and to OFF in command mode
10.4.4Notes
See the corresponding module system integration manual for the DSR behavior during the initialization
phase of the module.
10.5DTE-DCE character framing +ICF
+ICF
Modules All products
Syntax PIN required Settings saved Can be aborted Response time Error referenceAttributes
partial Yes No No - +CME Error
10.5.1Description
Sets the local serial port start-stop (asynchronous) character framing which is used in information interchange
between DCE and DTE. Value 0 corresponds to the auto-detect case (if autobauding is supported).
The following restrictions must be reminded:
If a data frame format refers to a frame without parity (ex. Format 3), the command is accepted, but
the parity value is ignored; it is returned by the AT+ICF read command (and displayed by AT&V) but
it has no meaning
The command setting is ignored when the AT command interface runs on the USB or on the SPI
interface