Parameter Type Description
<seq> Number Sequence number of the current short message (1-255)
<max> Number Maximum number of short messages in the concatenated short message (1-255)
<iei> Number Information Element Identifier, the possible values are the following:
0: Concatenated short messages, 8-bit reference number
8: Concatenated short messages, 16-bit reference number
<ref> Number Concatenated short message reference number:
0-255: Concatenated short messages, 8-bit reference number case
0-65535: Concatenated short messages, 16-bit reference number case
<text> String SMS String
<index> Number Storage position
9.22More messages to send +CMMS
+CMMS
Modules All products
Syntax PIN required Settings saved Can be aborted Response time Error referenceAttributes
full Yes No No - +CMS Error
9.22.1Description
Controls the continuity of SMS relay protocol link. When enabled, multiple SMS messages can be sent much
faster as link is kept open.
9.22.2Syntax
Type Syntax Response Example
Set AT+CMMS=[<mode>] OK AT+CMMS=2
OK
Read AT+CMMS? +CMMS: <mode>
OK
+CMMS: 2
OK
Test AT+CMMS=? +CMMS: (list of supported
<mode>s)
OK
+CMMS: (0-2)
OK
9.22.3Defined values
Parameter Type Description
<mode> Number Allowed values:
0 (default value): disabled
1: keep enabled until the time between the response of the latest message send
command (such as +CMGS) and the next send command exceeds 5 s, then close
the link and switch <mode> automatically back to 0
2: keep permanently enabled. The link is closed after each send sequence, but
<mode> is not switched back to 0