1.2. Mounting the Gateway and Repeater
The Gateway enclosure has a set of mounting tabs integrated into the enclosure, and the Repeater is
supplied with a plastic mounting plate. When securing either, the correct fasteners for the wall type
must be used.
For hollow wall construction studded with metal or wood framing and sheathed with Drywall,
Plaster or Plywood, an appropriate hollow wall such as a 3/16 toggle bolt or #10 re-usable
anchor.
Typical drill size is ½” for the 3/16 toggle bolt.
Each of the four Re-Usable Anchors used must be rated for 10 lb. (4.6 kg) minimum and be the
appropriate size for the sheathing thickness. Use #10 size minimum.
Typical drill size is 3/8” for the #10 re-usable anchor shown. Follow the manufacturer’s
instructions.
If the rear side of the sheathing is accessible, it is alternately acceptable to bolt the units to the
wall sheathing using four #10-#12 Pan Head Steel Machine Screws with fender washers and lock
nuts behind the sheathing. Length used must be adequate to fully engage all threads on the
nuts.
For concrete or masonry wall construction, use 3/16” concrete screws. Each of the four screws
must be rated for 10 lb (4.6 kg) minimum.
Typical drill size is 5/32” for the 3/16” concrete screw. Follow the manufacturer’s instructions.
Follow the manufacturer’s recommendation for drill depth for screws being used.