User's Manual
© SENSITECH INC. CONFIDENTIAL – CONTROLLED DOCUMENT
Page 73 of 83
A Carrier Corp. Company
PART NUMBER T82002163
REV A
Motor driving pulse rate:
Motor driving speed varies with driving voltage. It is determined with the following formula:
Motor driving speed (pps) = [200 * (Vp) – 600]
Therefore, for our application Vp = 6.25VDC.
As a result, [200 * (6.25) – 600] = 650 pps
11.0 Control Board
Dip Switch Setting:
Pin No. Function ON OFF
DS1-1 Auto Cutter X
1-2 CR Selection X
1-3 Print Density X
1-4 DTR/XON-XOFF X
1-5 Baud Rate X
1-6 Baud Rate X
1-7 Baud Rate X
1-8 Baud Rate X