REV A
Note: For Figure 12-17, UP2OCR[SEOS] = 4 for USB client and UP2OCR[SEOS] = 5 for USB host.
Interface to External Charge Pump Device
In addition to the interface options described in Section 12.5.4, the UDC provides control outputs
and interrupt inputs to drive and monitor an external charge pump device. To do so, the USB D+
and D– signals can be output using the on-chip OTG transceiver and the Vbus interface provided
by an external charge pump device. In this mode, UP2OCR[HXS] is used control multiplexors to
select between UDC and USB host controller D+, D–, and transmit enable signals to be output
through the USB host controller port 2 transceiver. In addition, USB Port 2 Output Control
Register (UP2OCR) provides the charge pump Vbus enable (CPVEN) and charge pump Vbus
pulse enable (CPVPE) control output bits used to enable the driving of Vbus and to enable the
driving of pulses on Vbus, respectively. Additionally, USB Port 2 Output Control Register
(UP2OCR) provides the Vbus valid 4.0-V, Vbus valid 4.4-V, session valid, and session request
protocol detected interrupt inputs to interface to the external charge pump device. Figure 12-18
illustrates the OTG connections to an external charge pump device.
Figure 12-18. Connection to External OTG Charge Pump