User's Manual
SPM-U User Manual
Default definition
Clock Mode
■ Default value is Monday.
■ In any week day, Digit default value →12:00
Schedule Mode ■ 7 days and all day are ON.
Setup Mode
■ PAN ID(5 Digit) default value →00001
■ Channel ID(2 Digit) default value→11
■ Appliance ID default value→01
■ Electricity rate default value→0.51
■ Clear cumulated data default value →NO
■ Restore Default value →NO
Specifications
Measurement Meter
Current Range 10mA~15A
Volt Range AC90~264Volt
Power Range 99,999KWh
Accumulated Energy Range 0~3,960W
CO Emission Yes
Electricity Cost Setting Yes
Measurement Accuracy ±1%
WPAN
Frequency Range
2.4~2.4835GHz
Transmission Range 120m
Network Topology Star/Tree
Data Rate 250Kbps
Typical conducted power +3.3dBm
Interface/Power Supply
Antenna Built-in PCB antenna
Display Panel LCD
Memory 128Kbyte
Operating Voltage AC90V~264V/50Hz~60Hz
Operating Power 2W(power on), under 1W(power off)
Mechanism Description
Design LCD display with one hole socket
Socket UL (125V,15A)
Dimension (L*W*H) 100×117×37.4mm
Weight 0.36kg
Operating Temperature Range -10~60℃
Storage Temperature Range -20~70℃