PORTABLE EXTRACTOR Operating Instructions MODELS: 406-135MO 10070260 406-131MO 10070240 Read these instructions before using the machine N 86038580 02/08/07 PRV NO.
MACHINE DATA LOG/OVERVIEW MODEL _______________________________________ DATE OF PURCHASE __________________________ SERIAL NUMBER ______________________________ SALES REPRESENTATIVE # _____________________ DEALER NAME ________________________________ OPERATIONS GUIDE NUMBER ___________________ PUBLISHED __________________________________________ YOUR DEALER Name: __________________________________________________________________________________________________ Address: __________________________________
TABLE OF CONTENTS Machine Data Log/Overview.........................1 Table of Contents..........................................2 HOW TO USE THIS MANUAL How to use this Manual.................................1-1 SAFETY Important Safety Instructions ........................2-1 Hazard Intensity Level. .................................2-2 Safety Label Location. ..................................2-3 Grounding Instructions..................................2-4 GROUP PARTS LIST Pump Group (50 psi) ............
HOW TO USE THIS MANUAL This manual contains the following sections: - - HOW TO USE THIS MANUAL SAFETY OPERATIONS MAINTENANCE PARTS LIST The HOW TO USE THIS MANUAL section will tell you how to find important information for ordering correct repair parts. Parts may be ordered from authorized dealers. When placing an order for parts, the machine model and machine serial number are important. Refer to the MACHINE DATA box which is filled out during the installation of your machine.
SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance, basic precaution must always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE. This machine is for commercial use. ! WARNING: To reduce the risk of fire, electric shock, or injury: Connect to a properly grounded outlet. See Grounding Instructions. Do not leave the machine unattended. Unplug machine from outlet when not in use and before maintenance or service. Use only indoors.
HAZARD INTENSITY LEVEL The following symbols are used throughout this guide as indicated in their descriptions: HAZARD INTENSITY LEVEL There are three levels of hazard intensity identified by signal words -WARNING and CAUTION and FOR SAFETY. The level of hazard intensity is determined by the following definitions: ! WARNING WARNING - Hazards or unsafe practices which COULD result in severe personal injury or death.
SAFETY LABEL LOCATION NOTE: These drawings indicate the location of safety labels on the machine. If at any time the labels become illegible, promptly replace them. LABEL WARNING 86242230 PRV NO.
GROUNDING INSTRUCTIONS THIS PRODUCT IS FOR COMMERCIAL USE ONLY. ELECTRICAL: In the USA this machine operates on a standard 15 amp 115V, 60 hz, A.C. power circuit . The amp, hertz, and voltage are listed on the data label found on each machine. Using voltages above or below those indicated on the data label will cause serious damage to the motors.
TECHNICAL SPECIFICATIONS ITEM Electrical Vacuum Motor Solution Pump MEASURE 115 Volt, 60hz Single 3 stage 50 psi 100 psi 7 gal (26 L) 6 gal (22 L) 50 lbs (110 kg) 105 lbs (230 kg) 35 inches (88.90 cm) 28.5 inches (72.39 cm) 25 inches (63.50 cm) 15.5 inches (39.37 cm) 22 feet (6.
CONTROLS ON ON PUMP VAC OFF OFF 2 1 3-2 1. Vacuum Switch 2.
MACHINE OPERATION GENERAL INFORMATION As the carpet is being cleaned, check to see if there is foam building up in the recovery bucket. Add a little defoaming compound to the recovery tank but never to the solution tank. For infrequent use or long periods of storage, flush the system with a neutralizing solution of 1 quart white vinegar mixed with 2 gallons hot water. Flush the system with clean hot water after neutralizing.
MAINTENANCE DAILY MAINTENANCE PERIODIC MAINTENANCE Unplug power cord(s) before servicing or making any repairs. 1. Flush the entire system, including floor tool, hand tool, etc., with 1 to 3 gallons of clean, hot water. 2. Vacuum out the solution tank. 3. Rinse tank with fresh water. Periodically inspect the recovery tank and decontaminate if necessary, using a Hospital Grade Virucide or a 1-10 bleach to water solution. Wastewater should be disposed of properly. 4.
MAINTENANCE Only qualified maintenance personnel are to perform the Vacuum Motor Carbon Brushes Replacement (Ametek) End Cap following repairs. VACUUM MOTOR REPLACEMENT 1. Turn off all switches and unplug machine. Carbon Brushes WARNING: The green ground wire must be attached for safe operation. See wiring diagram. 2. Remove recovery tank. 3. Locate the vacuum motor wires and disconnect at the connector. 4. Remove the vacuum motor. 5. Reverse process to install vacuum motor.
MAINTENANCE PUMP REPLACEMENT KITS SHURFLO 50 PSI Pump Head Replacement 86251050 PRV NO. 65188 Diaphragm 86255110 PRV NO. 29207 Valve Asm 86258840 PRV NO. 84162 PUMP REPLACEMENT PARTS FOR FLOJET 100 PSI (86251110 – PRV N0. 65219) DIAPHRAM 86235120 PRV NO. 29219 86191390 PRV NO. 65240 PUMP HEAD 86258860 PRV NO. 84166 VALVE ASM 86247360 PRV NO. 53245 MOTOR PUMP REPLACEMENT PARTS FOR SHURFLO 100 PSI (86201430 - PRV NO. 250-64A) Pump Head Replacement 86251040 PRV NO.
TROUBLESHOOTING PROBLEM Loss of Power Electrical shock CAUSE SOLUTION Dead electrical circuit Faulty power cord Equipment not grounding Receptacle not grounded Check building circuit breaker or fuse box.
PUMP GROUP (50 PSI) 1 2 3 5 4 6 7 3 2 8 5-1 SENSEI 86038580 02/08/07
PUMP GROUP (50 PSI) REF PART NO. PRV NO. QTY DESCRIPTION 1 2 3 86280840 86233150 86001550 39049 20042 40043 1 2 2 HOSE, 3/8” RUBBER X 11’ CLAMP, 3/8 HOSE (D-SLOT) HOSEBARB, 3/8 MPT X 3/8 90D 4 86251160 65233 1 PUMP, 120V LOW PRESSURE 5 6 7 8 86199960 86010630 86273830 86281250 110-22 87013 70020 39311 4 2 2 1 GROMMET 6 GAL. PORT WASHER, 1/4 ID X 5/8 OD SS SCR, 1/4-20 X 1/2 HHCS SS NP HOSE, 3/8ID SGLBRD RBR X 14” SENSEI 86038580 02/08/07 SERIAL NO.
PUMP GROUP (100 PSI) 1 2 3 5A 5B 6 7 3 2 8 5-3 SENSEI 86038580 02/08/07
PUMP GROUP (100 PSI) REF PART NO. PRV NO. QTY 1 2 3 4 5A 5B 6 7 8 86280840 86233150 86001550 86201430 86251110 86010630 86273780 86281250 39049 20042 40043 OPEN 250-64A 65219 87013 70015 39311 1 2 2 1 1 2 2 1 DESCRIPTION SERIAL NO.
RECOVERY TANK GROUP 3 4 26 1 2 25 28 5 15 24 27 6 23 7 9 22 21 10 20 19 18 17 11 12 16 13 14 5-5 8 15 SENSEI 86038580 02/08/07
RECOVERY TANK GROUP REF PART NO. PRV NO.
SOLUTION TANK GROUP 4 * PARTS INSIDE 5 1 TANK 6 3 38 40 39 * 9 7 39 2 10 37 36 6 8 41 6 11 42 CONNECT TO PUMP ASM 34 12 15 6 14 33 43 13 31 18 18 32 30 19 20 22 16 29 26 27 21 17 23 23 25 24 5-7 SENSEI 86038580 02/08/07 28 35
SOLUTION TANK GROUP REF PART NO. PRV NO.
VACUUM MOTOR GROUP 5 1 4 2 3 5-9 SENSEI 86038580 02/08/07
VACUUM MOTOR GROUP REF PART NO. PRV NO. QTY 1 2 3 4 5 86201950 86010630 86273970 86258420 86135320 86135300 86003720 065-24E 87013 70062 53130 140687 140676 35011 3 3 3 1 1 DESCRIPTION VAC SPACER 3 1/8 WASHER, 1/4 ID X 5/8 OD SS SCR, 1/4-20 X 4 HHCS GR5 PLTD VAC MOTOR, 120V 5.7 3ST W/O TB BRUSH SET, 120V VAC WINDSOR BRUSH SET, 120V 3ST VAC AMETEK GASKET, 3/8T 5.7 VAC FAN SEAL SENSEI 86038580 02/08/07 SERIAL NO.
WIRING DIAGRAM 5-11 SENSEI 86038580 02/08/07
SUGGESTED SPARE PARTS PART NO. PRV NO. 86003680 86002620 86161470 86256960 86202160 86003720 86200510 86135320 86135300 34380 260-64A 11-800444 72142 320-05 35011 140-12 140687 140676 DESCRIPTION FLOAT SHUT OFF ACCESS COVER CLEAR 6” W/RIM ELBOW, 1.5 FS X FS 45D PVC SWITCH SPST 15A EURO ROCKER VELCRO STRAPS GASKET, 3/8T 5.7 VAC FAN SEAL KNOB 1/4-20 X 3/4 S/S CUPPOINT BRUSH SET, 120V VAC WINDSOR BRUSH SET, 120V 3ST VAC AMETEK SENSEI 86038580 02/08/07 SERIAL NO.
LIMITED WARRANTY The foregoing constitutes Century 400’s entire warranty and no other warranty, liability, contingency or responsibility, direct, indirect, consequential or in any way connected with the sale or operation of Century 400 machines or chemical products, either as expressed or implied, will be honored.