Product Manual

6
Other Design Features: thermally controlled cooling fan, GFCI outlet protection,
and Remote LED Display Panel or “On/Off” switch hookup.
Unit Protection: Automatic electronic short circuit/overload protection,
Automatic over temperature shutdown, and AC output circuit breaker(s).
Battery Protection: Automatic low battery shutdown at 10.5VDC with in-rush
delay.
Temperature Compensated Charging: Allows for proper temperature charging
across the operating range of the inverter.
Auto Sleep Mode: When the LED Display Panel is used, the inverter can be
programmed to go to sleep after no load is detected over programmed interval.
Optional LCD Remote: For an additional cost, we have an LCD remote available
(1) DC input connections: Connects to the battery bank.
(2) Bonding lug: Connects to the ground system.
(3) AC Input & Output (hardwired): Terminal blocks are provided behind
front access cover for hardwiring AC Input and Output.
(4) Temp. Sense Connector Port: Connects to the temp. comp. cable
(5) Output Breaker, Branch Breaker: Trips to protect the inverter’s internal
circuitry from shorted AC loads or overload situations.
(6) AC Wiring Plate: Remove this plate to access the AC wiring terminal block
or to replace a GFCI outlet.
(7) GFCI: Provides 120VAC output. Only replace with same model GFCI.
PHYSICAL DESCRIPTION
OTHER DESIGN FEATURES
1 2 3
65
74
8