28
11
11.5
12
12.5
13
13.5
14
14.5
15
15.5
16
-20 0 20 40 60 80 100 120 140
Volts
Temp F
Charger Temperature Compensation, Flooded Lead Acid
acceptance
float
Maximum output of
15.0 volts to protect
vehicle electronics
Charger
reduced
at 122 F
Acceptance Voltage 14.6 at 77 F
Float Voltage 13.2 at 77 F
Charger
shut down
at 140 F
NOTE – GFCI Outlets: It is advisable when replacing a GFCI outlet to only use
the exact replacement part unless instructed to do otherwise by the factory. Other
types may fail to operate properly when connected to this unit.
Part Number Item Description
251048 Compression lu
g
s for battery cables (2 included)
431021 Fuse holder with cove
r
430010 Fuse 200A, ANN-200
430012 Fuse 300A, ANN-300
430019 Fuse 400A,
A
NN-400
430067 Fuse 600A, ANN-600
611622-X
X
Temperature compensation cable (XX=length in feet)
611877 Temp. Comp. Cable Bypass dongle
625000 LED Display Remote extension kit.
430001 Faceless GFCI Outlet, Leviton X7590
430005 GFCI Outlet, Leviton N7899
Accessories & Re
p
lacement Parts
Char
g
er Out
p
ut vs. Tem
p