Product Manual

23
5) Charger Off High Temperature
chgr OFF high temp
The charger is off due to a high temperature condition (>60°C/140°F). The
Red “FAULT” LED is on. The charger will turn back on automatically when
the temperature is < 45°C/113°F.
6) Charger Off Battery Temperature
chgr OFF batt temp
The charger is off due to a high battery temperature (>47°C/117°F-
50°C/122°F). The Red “FAULT” LED is on. Check the battery
compartment for proper ventilation.
7) Charger Off Battery Probe
chgr OFF batt prOb
The charger is off due to a shorted or open (missing) temperature
compensations sensor. The Red “FAULT” LED is on. Check the connections.
8) Charger Off High Battery
chgr OFF high batt
The charger is operating in a high DC output voltage condition. The Red
“FAULT” LED is on. Disconnect other battery charger or source and reset.
9) Charger Warm Battery
chgr warm batt
The charger reduced output due to warm battery temperature. The Red
“FAULT” LED is on. Check battery compartment for proper ventilation.