Product Manual

22
Look at the “LED DISPLAY PANEL MESSAGES” and “LED STATUS CHART” below
for LED descriptions. See also the troubleshooting section for more troubleshooting
information.
WARNING: Do not remove chassis cover. No user-serviceable parts
inside.
Call or e-mail customer service for free consultation during business hours (7:30am-5:30pm
central time) at 1-800-553-6418 or 1-651-653-7000; fax 1-888-439-3565 or 1-651-653-
7600
E-mail: inverterinfo@sensata.com
; http://dimensions.sensata.com
1) Inverter Off Low Battery
Inv OFF LOW batt
The inverter is off due to a low battery voltage condition (<=10.5 volts for 5
seconds). Both the Amber “ON/STBY” and Red “FAULT” LED’s are on.
Check battery charge and DC wiring cable size.
2) Inverter Off Overload
Inv OFF OL
The inverter is off due to an overload condition. The Red “FAULT” LED is
on. Remove one or more loads from the output of the inverter. Reset the
inverter.
3) Inverter Off High Temperature
Inv OFF high temp
The inverter is off due to a high temperature condition (>60°C/140°F). Both
the Amber “ON/STBY” and Red “FAULT” LED’s are on. The inverter will
turn back on when the temperature is < 45°C/113°F.
4) Inverter Off High Battery
Inv OFF high batt
The inverter is off due to a high charging voltage condition (>16.9 volts) and
the display reports the value. Both the Amber “ON/STBY” and Red
“FAULT” LED’s are on. Inverter restarts at 15.5 volts. Check the vehicle
alternator/regulator.
TROUBLESHOOTING GUIDE
LED Dis
p
la
y
Panel Messa