Product Manual
17
2) AC Input Limit (Charger AC current limit)
The maximum AC current that the charger will be allowed to draw is
adjustable. This value can be set to 30-0A (maximum value is factory set based
on model). The default setting is for 15 amps. Press [MENU] to display the
current setting. The message will then scroll:
AC In Lmt 15A
To change the value press [DISPLAY/SELECT] and the value will decrease in
5A increments. The charger stores the last value shown on the display.
3) Charger Modes
The charger has three modes of operation; Bulk, Accept, and Float. The
display panel will state which mode the charger is in when shore power is
applied. The mode along with the charge voltage and current will be
displayed.
Bulk Mode:
chgr bulk 12.3v 50a
Accept Mode:
chgr acpt 14.4v 15a
Float Mode:
chgr FLOt 13.1v 0a
4) Temperature Compensation Cable or Dongle
If the temperature compensation Cable or Dongle is not connected to the
“Temp. Sense” connector on the inverter; the battery charger will not
function, the red “FAULT” LED will come on, and the display will show:
chgr OFF batt prOb
Check to make sure that the cable is connected.