Product Manual

16
press the [DISPLAY/SELECT] key. The display will show “LO BATT”
followed by the recorded minimum low input condition (trough) voltage. The
mode will stay active for 1 minute or until the [BATT TEST] or [MENU] key
is pressed. The following message shows the low point at 10.1 volts.
Lo batt 10.1v
If there is not a value stored, the message will just say “Lo batt ---” and not list
any voltage.
You can clear the stored value manually by pressing the [DISPLAY/SELECT]
key while the message is scrolling. You will then see the following flash twice:
cLr batt
A newly recorded value will also clear the old value and replace it with the new.
6) Auto Sleep Mode
This feature is used to turn the inverter off if there has been zero watts drawn
for the set amount of time. For example if the sleep mode is set to 30 minutes
and 30 minutes of time has elapsed with no power being drawn from the
inverter, the inverter will shut off. The inverter must then be manually turned
back on again when needed. You can adjust this setting by pressing the
[MENU] key twice. You will then see:
Avto SLEp OFF
To change the setting press [DISPLAY/SELECT] repeatedly until the desired
setting appears. The options are OFF, 30M, and 15M. The default setting is
Off.
1) Bypass Relay: The loads attached to the inverter output will operate directly
from the external AC power line independently of the inverter ON/OFF
status. If the inverter is left ON (standby mode), the built-in bypass relay will
automatically cycle back and forth between “Inverter Power” mode and
“External Power” mode depending on the availability of the external AC power
line.
BATTERY CHARGER
The battery charger will engage automatically and independently of the inverter
ON/OFF status. The 3-step charging process modes are; Bulk, Acceptance, and
Float.
External Power Mode (Usin
g
LED Dis
p
la
y
Panel)