Spec Sheet

The World Depends on Sensors and Controls
4467 White Bear Pkwy
St. Paul, MN 55110 USA
800-553-6418
www.SensataPower.com
The 12LP15 inverter and 12LPC15 inverter/charger from Dimensions provides pure sine wave power.
12LP15 AND 12LPC15
INVERTER AND INVERTER/CHARGER
Pure Sine Wave Output
The 12LP15/12LPC15 Features:
The 12LP15 is an inverter only.
The 12LPC15 is an inverter/charger with
a 20A bypass.
Remote: Optional remote on/off switch
for inverter control.
Cooling: Thermally controlled cooling fan.
Unit Protection: Provides automatic
electronic short circuit/overload
protection, automatic over-temperature
March 2018 Rev B Part #131506
12LP15 12LPC15
INVERTER SPECIFICATIONS
Input Voltage: (Vdc) 10.5-15.0 10.5-15.0
DC Surge Voltage (Vdc) Up to 24Vdc Up to 24Vdc
Output Voltage (Vac) 120 +/- 5% 120 +/- 5%
Output Frequency (Hz) 60 +/- .05% 60 +/- .05%
THD < 5% at 12.6Vdc and 1500W < 5% at 12.6Vdc and 1500W
Output Waveform Pure Sine < 5% THD Pure Sine < 5% THD
Output Power (Watts Cont.) 1500 1500
Output Current (Aac Cont.) 12.5 12.5
Input Current (Adc Cont.) Up to 167 at 12.6Vdc Up to 167 at 12.6Vdc
Input Current (Adc Cont.) Up to 190 at 10.5Vdc Up to 190 at 10.5Vdc
Peak Power (Watts) 3000 3000
Peak Output (Aac) 25.0 25.0
Motor Starting Rating (h.p.) 1/2 1/2
Inverter Efficiency Up to 80% Up to 80%
Charger Input Voltage (Vrms) 100 – 130
Charger Output Current (Adc) 65
Input Current Bypass (Arms) 20
Weight (lbs.) 20 20
Dimensions in. (L x W x H) 19.0” x 9.75” x 4.8” * 19.0” x 9.75” x 4.8” *
Operating Temperature -40C to 65C (0F to 149F) ** -40C to 65C (0F to 149F) **
Agency Listings UL458, E100666 UL458, E100666
shutdown, and an AC input and
output circuit breaker.
Local Status LED: Provides inverter
operation mode and troubleshooting
information at a glance.
Low Battery Protection: Automatically
shuts down at 10.5 VDC with in-rush delay.
Surge: Surge rating for motor loads.
GFCI receptacle output and hardwired
AC output.
“A” option – AC hardwired output
protected by GFCI.
“H” option – AC hardwired output only,
no GFCI.
“R” option – Remote only, local
switch inactive.
Other model configurations available.
Contact factory.
UL Listing to UL 458 6th Edition
* Length includes DC terminals and handle.
** The operating temp range for a GFCI is
-20°C to 65°C.
Testing for specifications at 25°C and 12.6Vdc,
measured at the inverter input terminals.
Specifications subject to change without notice.