1. GENERAL
1.01 Dimensions inverters have been designed
and manufactured for many user applications and
long life. They utilize patented construction
methods and high technology electronic parts and
circuitry.
1.02
CAUTION:
Inverters produce hazardous
voltage. To avoid risk of harm or fire the unit must
be properly installed. There are no user service-
able parts inside, do not remove the cover.
CAUTION:
The inverter should not be mounted in
a location that may be exposed to rain or spray.
CAUTION:
The inverter should not be installed in
a zero clearance enclosure.
CAUTION:
Damage to the inverter will occur if
correct polarity is not observed when installing
the DC input cables.
CAUTION:
Damage to the inverter will occur if an
external AC power source is applied to the inverter’s
AC output or its hardwire output.
CAUTION:
The inverter contains a circuit breaker
and capacitor that may produce a spark. Do not
mount in a confined battery or gas compartment.
CAUTION:
Working in the vicinity of lead - acid
batteries is dangerous. Batteries generate explo-
sive gases during operation. There is a risk of acid
exposure. There is also a risk of high current
discharge from shorting the battery that can cause
fire and explosion.
CAUTION:
Be sure the inverter's circuit breaker or
fuse are turned "
OFF" during installation.
2. DESCRIPTION
2.01 The inverter converts 12 VDC to 120
VAC, 60 HZ, having a pure-sine wave form.
2.02 The inverter has a controlled frequency
at 60 HZ
+ 0.6Hz.
2.03
The inverter has internal protection
against output short circuit, output overload and
high temperature conditions. Also, there is a
thermally controlled cooling fan.
2.04 The inverter is designed to operate
any 120 VAC, 60 HZ, single phase appliance,
equipment or tool within its power ratings.
Inverter Rating
Model: 12/400N
Output Power (constant): 400 Watts
Output Current: Up to 3 Amps
Peak Output: 800 Watts
Input Current: Up to 40 Amps DC
Weight: 14 Lb
Size: 12.5" x 6" x 5"
3. INSTALLATION
3.01 The following instructions should be
thoroughly read and understood before installa-
tion.
3.02
CAUTION:
Inverters produce hazard-
ous voltages, to avoid risk of harm or fire the unit
must be properly installed.
CAUTION:
Damage to the inverter will occur if
correct polarity is not observed when installing the
DC input cables.
CAUTION:
Damage to the inverter will occur if an