Product Manual
12
 SPECIFICATIONS
GENERAL SPECIFICATIONS 12/800N 12/1200N 12/1500N 12/1800N 12/2400N 12/3000N 12/3600N
Output Power (Watts 
Continous)
800 1200 1500 1800 2400 3000 3600
Output Current (Amps AC) Up to 7 Up to 10 Up to 12.5 Up to 15 Up to 20 Up to 25 Up to 30
Peak Output (Amps DC) 12 21 24 44 91 91 136
Input Current (Amps DC) Up to 80 Up to 120 Up to 150 Up to 180 Up to 240 Up to 300 Up to 360
Input Voltage (Volts DC) 10.5 to 20
Output Voltage (Pure Sine) 120 VAC ± 5%
Output Frequency 60 Hz ± 0.05%
Output Wave Form Pure Sine Wave, <5%
Effenciency (Inverter) Up to 88%
Operating Temperature 0º to 140º F [-20º to 60º C]
Case Size (L x W x H) 15 x 8.2 x 7.5 15 x 16 x 7.5 15 x 17 x 10
Weight (Lbs) 25 29 29 42 56 58 80
 OTHER DESIGN FEATURES
 UNIT PROTECTION
 BATTERY PROTECTION
• High performance construction and coolong methods.
• Microprocessor controlled.
• Thermally controlled cooling fan.
• Enclosed AC and DC cable connections.
• Remote ON/OFF switch hookup.
• GFCI outlet protection.
• LED indication of External power, Inverter power, Low input voltage, High temperature, and 
Overload.
• Battery voltage indicator with push-to-test (12/1800N, 12/2400N, 12/3000N, and 12/3600N) 
only.
• Remote control “R”.
•  Automatic electronic short circuit/overload protection.
•  Automatic over temperature shutdown.
•  Output circuit breakers.
•  Automatic low battery shutdown at 10.5 VDC (with in-rush delay).
Usage: Any 120 VAC, 60 Hz single phase product within the inverter’s power rating.
Warranty: See product label on top of the inverter for warranty period.