Datasheet

(1) Voltages are reference to GND (Ground = 0 VDC) P2
(2) PLVI voltage can go up to max. supply voltage without damage
GENERAL NOTES
DataSheet
Control Relays
Do not forget to visit us at:
www.crydom.com
Copyright © 2017 Crydom Inc. Specifications subject to change without notice.
INPUT SPECIFICATIONS
(1)
Description
Control Voltage Range (VDC)
Input Current Range [mA] [P1]
Nominal Input Impedance [Ohms] [P3]
Control Must Operate Voltage "On"[VDC][P3]
Control Must Release Voltage "Off" [VDC][P3]
Control Input Current [mA][P3]
PLV Range Option A [VDC][P4] (2)
PLV Range Option B [VDC][P4] (2)
PLV Range Option C [VDC][P4] (2)
DC Control
8-32 VDC
28-30 VDC
30K
5-32
0-4
0-1.25
0-5
0-7
0-10
PLV Range Option D [VDC][P4] (2)
Nominal Input Impedance Option A,B,C[ohms][P4]
Nominal Input Impedance Option D [ohms][P4]
4-20
20-K
220
OUTPUT STATUS FUNCTIONS
Conditions
Initial Logic Supply On
Load Voltage Missing / Load Open (w/control disabled)
Load Voltage Missing / Load Open (w/control enabled)
Analog Input < Threshold
Analog Input < Threshold < max
Analog Input > max
LED
Flash Once
Flash Once Intermittenly
Flash Twice Intermittently
Off
Varying On/Off
On, Bright
GENERAL SPECIFICATIONS
ParametersDescription
Dielectric Strength, Input/Output/Base (50/60Hz) 4000 VRMS
Minimum Insulation Resistance (@ 500 VDC) 10
9
Ohm
Maximum Capacitance, Input/Output
10 pF
Ambient Operating Temperature Range -20 to 80°C
Ambient Storage Temperature Range -40 to 125 °C
3.0 oz (86.5g)
Weight (typical)
Thermally conductive Epoxy
Encapsulation
Screws and Saddle Clamps Furnished, Unmounted
Terminals-Control
Terminals-Power
Barrier Strip Screw Terminals
Recommended Terminal Screw Torque Range:
8-32 Screws -20 in. lbs.(Screws dry without grase)