Datasheet
Page 8
www.sensata.com
Copyright © 2019 Sensata Technologies, Inc.
Table 1. Electromagnetic Compatibility / Electromagnetic Interference
Generic Standard Specific Standard Test Specification Level Performance
IEC 61000-6-2
Immunity for Industrial
Environments
Electrostatic Discharge
IEC 61000-4-2
8kV air discharge Criterion A
6kV contact discharge Criterion A
Fast transients (burst)
IEC 61000-4-4
Output 2kV, 5kHz, 100kHz Criterion B
Input 1kV, 5kHz, 100kHz Criterion B
Surge
IEC 61000-4-5
Output
1kV Line to Neutral Criterion B
2kV Line to Earth Criterion B
2kV Neutral to Earth Criterion B
Input
500V Line to Neutral Criterion B
1kV Line to Earth Criterion B
1kV Neutral to Earth Criterion B
IEC 60947-4-3
Environment B Low
voltage domestic,
commercial and light
industrial installations
Conducted
Disturbances CISPR 11
Frequency, MHz Quasi-peak, dB(uV) Average, dB(uV)
Class B Group 1 &
Group 2
0.15 to 0.5 66 to 56 56 to 46
0.5 to 5 56 46
5 to 30 60 50
240VAC @40A & 440VAC @35A with Resistive Load
Conformances Environmental
Vibration
Resistance
IEC 60068-2-6
Shock
Resistance
IEC 60068-2-27
Electromagnetic
Interference
IEC 60947-4-3
(See Table 1)
Electromagnetic
Compatibility IEC
61000-6-2
(See Table 1)
Resistances
to heat and
fire
Amplitude
Range: 10-55 Hz,
Displacement
0.75mm
Peak Acceleration:
15g, Duration
11ms.
Conducted Disturbances
CISPR 11
IEC 61000-4-2 (ESD) IEC 60335-1,
Section 30
Directive
2006/95/
EC
Directive
2011/65/EU
GBT 26572-
2011
IEC 61000-4-4 (Burst)
IEC 61000-4-5 (Surge)
AGENCY APPROVALS & CERTIFICATIONS
Approvals (Tested and Certified According To)
E116950
UL 508 and C22.2 No.14 EN 62314