Datasheet
Page 4
www.sensata.com
Copyright © 2019 Sensata Technologies, Inc.
EQUIVALENT CIRCUIT BLOCK AND WIRING DIAGRAMS
SURGE CURRENT INFORMATION
DC
Trigger
Circuit
Current
Limiter
AC
-4
V
+3
2
1
INPUT
OUTPUT
+
-
V
Load
Load
A
B
Load can be wired in position A or B
DC Control
(7)
0
50
100
150
200
250
300
0.01 0.11 10
Surge Current (Amp) AC Peak
Surge Duration
(sec)
LNDxx25xx
0
100
200
300
400
500
600
700
0.01 0.11 10
Surge Current (Amp) AC Peak
Surge Duration
(sec)
LNDxx50xx
Single Pulse
0
100
200
300
400
500
600
700
800
900
1000
1100
0.01 0.11 10
Surge Current (Amp) AC Peak
Surge Duration
(sec)
LNDxx75xx
(6)