Datasheet

PRODUCT SELECTION
50A25AControl Voltage
4-32 VDC GN325DLZ GN350DLZ
18-36 VAC GN325ELZ GN350ELZ
90-140 VAC GN325BLZ GN350BLZ
AVAILABLE OPTIONS
OUTPUT SPECIFICATIONS (1)
50A25ADescription
Operating Voltage (47-63Hz) [Vrms ] (2) 48-600 48-600
Transient Overvoltage [Vpk, t=1 min.] 1200 1200
Static off-state dv/dt (V/µsec, Ta=25°C) (3) 500 500
Maximum Load Current [Arms] (4) 25 50
Minimum Load Current [mArms] 100 100
Maximum Off-State Leakage Current [mArms] (5) 0.06 0.06
1 Cycle surge current (50Hz) 275 710
1 Cycle surge current (60Hz) 300 750
1 Second surge current (Apk. Ta=25°C) 50/60 Hz 85 150
Forward Voltage Drop (Vpk @ Imax, Ta=25°C) 1.35 1.35
2
2
I T (50Hz, 1/2 cycle)
380 2520
I T (60Hz, 1/2 cycle)
370 2320
GN3 Series
Current ratings of 25 and 50 Amps
Output voltage rating: 48-600 VAC
Direct bond copper substrate
LED input status indicator
IP20 “touch-safe” cover
Transient protection built-in
UL508 endurance rating for enhanced reliability
UL/CSA/TUV Approved, CE Compliant to EN60950-1
180-260 VAC GN325ALZ GN350ALZ
Required for valid part number
For options only and not required for valid part number
Series
Operating Voltage
A: 180-260 VAC
B: 90-140 VAC
C: 4-32 VDC
D: 18-36 VAC
Rated Load Current
25: 25 Amps
50: 50 Amps
GN3 A L Z25
Datasheet
Panel Mount
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
Snubber Option
L: No Snubber (48-600 VAC)
S: Snubber Included (48-530 VAC)
Switching Type
R: Instantaneous Turn-on
Z: Zero voltage Turn-on
Thermal Resistance Junction to baseplate (Rjb) [°C/W] 0.24 0.12
HP Ratings at 120V / FLC [Arms] 0.75 / 6.4 1.5 / 12
HP Ratings at 240V / FLC [Arms] 1 / 4.2 3 / 9.6
HP Ratings at 480V / FLC [Arms] 3 / 4.8 7.5 / 11
HP Ratings at 600V / FLC [Arms] 5 / 6.1 10 / 11
Min/Max wire size 16/8 AWG 16/8 AWG
Screw Torque Range [in-lb/Nm] 18-20 / 2.03-2.26 18-20 / 2.03-2.26