Datasheet
DataSheet
Solid State Relay Timer
SeriesOneDR Timer
• 6 Amp AC and DC rated output
• Compact size (11mm wide)
• Dual SCR or MOSFET output
• AC/DC control
• Zero-crossing (resistive loads) or random-fire (inductive loads) AC output
• Timer status LED indicator
• UL listed, HP rated
• 8 Industry standard fuctions (A/At, B, C, D/Di, H/Ht, L/Li, Ac and Bw)
PRODUCT SELECTION
Control Voltage DC OutputAC Output
12-24 VAC/DC DRTx24D06x DRTx06D06
90-140 VAC/DC DRTx24B06x
180-280 VAC/DC DRTx24A06x
AVAILABLE OPTIONS
DRT
Series
Operating Voltage
06: 60 VDC
24: 280 VAC
Rated Load Current
06: 6 Amps
Control Voltage
D: 12-24 VAC/DC
A: 180-240 VAC/DC
B: 90-140 VAC/DC
Timing Function
A: A/At, Delay on Make
B: Single Shot
C: Delay on Break
H: H/Ht, Interval
L: L/Li, Repeat Cycle
U: Multifunction
(A/At, H/Ht, D/Di,
B, C, Ac & Bw)
Switching Type
(24 suffix only)
Blank: Zero Voltage Turn-On
R: Random Turn-On
0624 DA R
AC
Output
Only
Required for valid part number
For options only and not required for valid part number
OUTPUT SPECIFICATIONS
(1)
DRTx06DRTx24Description
Operating Voltage 24-280 VAC (47-440Hz) 1-48 VDC
Transient Overvoltage [Vpk] 600 60 VDC
Rated Load Current
(2)
6 Arms 6 A
Rated Load Current {UL508 Motor Controller}
(2)
[Arms] 3.6 Arms -
Minimum Load Current 150 mArms 2.5 mA
Maximum Off-State Leakage Current @ Rated Voltage 0.1 mArms 0.25 mA
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec]
(3)
500 -
Maximum Surge Current (AC output 1 cycle. DC output 10ms) 285/300 Apk (50/60Hz) 60 A
Maximum I²t for Fusing [A² sec] 410/375 (50/60Hz) -
Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.3 0.3 VDC
Maximum On-State Resistance (RDS-ON) [Ohms] - 0.034
HP rating UL 508/IEC60947[HP (KW)]: 240 VAC 1/3 (0.24) -
IEC 62314 LC-A [FLA] 6 A -
IEC 62314 LC-B [Kw] 0.24 -
Wire Size min/max (solid/stranded) [AWG/ IEC mm²]
(4)
22/12 [0.33/3.31] 22/12 [0.33/3.31]
Output Terminal Screw Torque [in lb (Nm)] 7.0 (0.8) 7.0 (0.8)
Do not forget to visit us at: www.crydom.com
Copyright © 2013 Crydom Inc. Specifications subject to change without notice.
Not all part number combinations are available.
Contact Crydom Technical Support for information on
the availability of a specific part number.
*