Datasheet
SWITCHING FREQUENCY/LOAD CHARACTERISTIC FOR ALL DEVICES
I
L
: Load Operating Current
I
R
: Rated Full Load Current [FLA]
I
D
: Direct-On-Line Inrush Current
t
L
: Load Operating Current Time
t
D
: Direct-On-Line Inrush Current Time
t
C
: Cycle Time
t
On
: On Time
t
Off
: Off Time
DataSheet
Solid State Contactor
Do not forget to visit us at: www.crydom.com
Copyright © 2014 Custom Sensors & Technologies. Specifications subject to change without notice.
Without overload relay (limit given by the contactor itself)
With overload relay (limit given by the overload relay itself)
t
D
(sec) 0.1 1 10 100
0.05 5000 2700 350 35
0.1 3200 1950 350 35
0.2 950 320 35
0.4 500 280 35
0.8 290 160 35
1.6 110 30
3.2 75 25
t
On
(sec)
t
D
(sec) 0.1 1 10 100
0.05 6000 3550 350 35
0.1 4100 3000 350 35
0.2 1300 350 35
0.4 700 320 35
0.8 400 320 35
1.6 125 35
3.2 90 35
t
On
(sec)
t
D
(sec) 0.1 1 10 100
0.05 7450 3200 350 35
0.1 4050 2100 350 35
0.2 1200 350 35
0.4 650 320 35
0.8 350 280 35
1.6 180 35
3.2 90 35
t
On
(sec)
t
D
(sec) 0.1 1 10 100
0.05 9000 3550 350 35
0.1 5400 3550 350 35
0.2 1700 350 35
0.4 850 350 35
0.8 560 350 35
1.6 240 35
3.2 180 35
t
On
(sec)
t
D
(sec) 0.1 1 10 100
0.05 2200 1650 330 30
0.1 1500 1000 280 28
0.2 550 255 26
0.4 250 150 24
0.8 80 60 20
1.6 40 16
3.2
t
On
(sec)
t
D
(sec) 0.1 1 10 100
0.05 2800 1800 320 35
0.1 1700 1300 310 32
0.2 650 290 30
0.4 300 200 26
0.8 200 90 25
1.6 65 25
3.2
t
On
(sec)
t
D
(sec) 0.1 1 10 100
0.05 5150 2800 260 35
0.1 2850 1920 250 34
0.2 1100 250 33
0.4 600 200 32
0.8 320 200 30
1.6 120 25
3.2 75 20
t
On
(sec)
t
D
(sec) 0.1 1 10 100
0.05 5600 3200 350 35
0.1 3200 2700 350 35
0.2 1400 350 35
0.4 700 350 35
0.8 350 280 35
1.6 170 35
3.2 80 25
t
On
(sec)
Table 1
• High inrush current (I
D
/I
R
= 4 to 7.2)
• Full load (I
L
/I
R
= 1)
Table 2
• High inrush current (I
D
/I
R
= 4 to 7.2)
• 60% load (I
L
/I
R
= 0.6)
Table 3
• Low inrush current (I
D
/I
R
< 4 )
• Full load (I
L
/I
R
= 1)
Table 4
• Low inrush current (I
D
/I
R
< 4 )
• 60% load (I
L
/I
R
= 0.6)
Table 5
• High inrush current (I
D
/I
R
= 4 to 7.2)
• Full load (I
L
/I
R
= 1)
Table 6
• High inrush current (I
D
/I
R
= 4 to 7.2)
• 60% load (I
L
/I
R
= 0.6)
Table 7
• Low inrush current (I
D
/I
R
< 4 )
• Full load (I
L
/I
R
= 1)
Table 8
• Low inrush current (I
D
/I
R
< 4 )
• 60% load (I
L
/I
R
= 0.6)
I
D
I
R
I
L
t
D
t
L
t
C
t
On
t
Off
MAXIMUM ALLOWABLE NUMBER OF STARTS PER HOUR DEPENDING ON THE STARTING
TIME t
D
AND THE ON PERIOD t
On
(as for standard IEC 60947-4-2) FOR ALL DEVICES
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- -
-
-
-
-
-
-
-