Brochure
solicon
DRC Series
Americas
Tel.: +1 (877) 502 5500
sales@crydom.com
EMEA
Tel.: +44 (0) 1202 606030
sales-europe@crydom.com
Asia
Tel.: +86 (0) 21 6065 7725
sales-cn@crydom.com
DRC Series Contactor
DIN Rail Mounted 3 Phase & Reversing Solid State Contactors
•
7.6 Amp Motor Controller rated Solid State Contactor
•
Load voltage range up to 530 VAC
•
Fits standard 35 mm DIN rail
•
LED input status indicator
•
AC or DC control
•
Zero crossing (resistive loads) or instantaneous turn-on (inductive loads) output
•
Built in Overvoltage Protection
•
Ultra-efficient thermal management design (Patented)
•
C-UL-US Listed, IEC Rated, CE & RoHS Compliant, Horsepower Rated
Start / Stop
Reversing
Output Specifications
DRCa3R48xxx
(A)
DRC3Pxxxx
Normally Open Suffix 2x, 1x
Option A
Input Specifications
(A)
Solid State Auxiliar Contacts
(A)
Operating Voltage Range (47-63 Hz) [Vrms]
Transient Overvoltage [Vpk] (B)
Maximum Off-State Leakage Current @ Rated Voltage [mArms]
Maximum Off-State dv/dt @ Maximum Rated Voltage [V/µsec]
Load Current, Resistive UL508/AC51 @ 40°C [Arms] (C)
Load Current, Motor Controller UL508/AC53 @ 480VAC [Arms] (C)
Minimum Load Current [Arms]
Maximum Surge Current [Apk] 1 Cycle 60Hz
Maximum Surge Current [Apk] 1 Cycle 50Hz
Maximum I
2
t for Fusing (8.33msec)[A
2
sec]
Maximum I
2
t for Fusing (10msec)[A
2
sec]
Maximum On-State Voltage Drop @ Rated Current [Vrms]
Minimum Power Factor (with Maximum Load)
Ratings according to UL 508/IEC60947-4-2 [HP/KW]: 240 VAC
Ratings according to UL 508/IEC60947-4-2 [HP/KW]: 400 VAC
Ratings according to UL 508/IEC60947-4-2 [HP/KW]: 480 VAC
48-530
1200
3
500
5
4.8
0.15
750
716
2330
2560
1.15 per channel
0.5
1 / 0.75
2 / 1.5
3 / 2.2
48-530
1200
3
500
7.6
7.6
0.15
750
716
2330
2560
1.15 per channel
0.5
2 / 1.5
3 / 2.2
5 / 3.7
48-415
1200
5
500
7.6
7.6
0.15
750
716
2330
2560
1.15 per channel
0.5
2 / 1.5
3 / 2.2
-
48-510
1600
5
500
7.6
7.6
0.15
625
597
1621
1779
1.15 per channel
0.5
2 / 1.5
3 / 2.2
5 / 3.7
DRC3Pxxxx2 DRC3R40xxx
Control Voltage Range
Minimum Turn-On Voltage (D)
Must Turn-Off Voltage
Minimum Input Current (for On-State) [mA ± 10%]
Maximum Input Current [mA ± 10%]
Nominal Input Impedance
Maximum Delay to Turn-On [msec] (E)
Maximum Turn-Off Time [msec] (F)
208-265 VAC
208 VAC
60 VAC
5.5
7.7
36 K
30
30
90-140 VAC
90 VAC
20 VAC
5
8
16.4 K
30
30
18-30 VAC / VDC
18 VAC / VDC
7 VAC / VDC
10
22
1.3 K
20
30
Option B Option D
Operating Voltage Range (47-63 Hz) [Vrms]
Transient Overvoltage [Vpk]
Maximum Load Current [Arms]
Minimum Load Current [mA]
Maximum Surge Current [Apk] 1 Cycle 60Hz
Maximum Surge Current [Apk] 1 Cycle 50Hz
Maximum I
2
t for Fusing (8.33msec)[A
2
sec]
Maximum I
2
t for Fusing (10msec)[A
2
sec]
Maximum Off-State Leakage Current @ Rated Voltage
Maximum Off-State dv/dt @ Maximum Rated Voltage [V/µsec]
Maximum Delay to Turn-On [msec] (E)
Maximum Turn-Off Time [msec] (F)
18-280
600
1
5
40
38
6.7
7.2
0.1 mArms
500
20
30
Normally Closed Suffix x1
18-280
600
1
5
40
38
6.7
7.2
5 mA
500
80
30
DRC3
General Specifications
(A)
Dielectric Strength, Input-Output to Baseplate (50/60Hz) [Vrms] (G)
Minimum Insulation Resistance (@ 500 VDC) [Ohm]
Maximum Capacitance, Input/Output [pF]
Ambient Operating Temperature Range [ºC]
Ambient Storage Temperature Range [ºC]
LED Status Indicator (color) (H)
Short Circuit Current Rating [KA] (J)
Weight (typical)
Housing Material
Housing Color
Humidity
3750
10
9
20
-30 to 80
-40 to 100
Forward (Green) / Reverse (Amber)
100
2 Controlled Legs (6.940 oz [196.7 g]) / 3 Controlled Legs (8.050 oz [228 g])
UL94 V-0
Black and Light Gray
85% Non-Condensing