Datasheet

Page 9
www.sensata.com
Copyright © 2019 Sensata Technologies, Inc.
AGENCY APPROVALS & CERTIFICATIONS
Approvals (Tested and Certified According To)
E116949
40047491
UL 508 and C22.2 No. 14 EN 62314
CONFORMANCES ENVIRONMENTAL
Vibration
Resistance IEC
60068-2-6
(9)(10)
Shock Resis-
tance IEC IEC
60068-2-27
(9)(10)
Resistances to
heat and fire
Amplitude Range:
10-55 Hz, Displace-
ment 0.75mm
Peak Acceleration:
15g, Duration 11ms.
IEC 60335-1,
Section 30
Directive
2006/95/EC
Directive
2011/65/EU
GBT 26572-2011
Electromagnetic Compatibility
Generic Standard Immunity Tests Test Specification Level Performance
IEC 61000-6-2
Immunity for Industrial Envi-
ronments"
Electrostatic Discharge
IEC 61000-4-2
8kV air discharge Criterion A
6kV contact discharge Criterion A
Fast transient (burst)
IEC 61000-4-4
Output 2kV, 5kHz, 100kHz Criterion B
Input 1kV, 5kHz, 100kHz Criterion B
Surge
IEC 61000-4-5
Output
1kV Line to Line Criterion B
2kV Line to Earth Criterion B
AC Input Option
1kV Line to Line Criterion A
2kV Line to Earth Criterion A
(1) Option available upon demand. Please contact your local Sensata representative for additional information.
(2) All parameters at 25°C unless otherwise specified per Channel.
(3) Output will self trigger between 900-1200 Vpk, not suitable for capacitive loads.
(4) Increase minimum voltage by 1 V for operations from -20 to -40°C.
(5) Turn-on time for Instantaneous turn-on versions is 0.1 msec.
(6) When protected with the appropriate class and rated fuse. For detailed info please contact Sensata Technical Support.
(7) No freezing or condensation allowed.
(8) For single surge pulse Tc=25°C; Tj=125°C. For AC Output SSRs, AC RMS value of surge current equals the peak value divided by 2 (1.414).
(9) Except when device is attached to a panel or flat surface with screws.
(10) Test conditions: Din Rail stoppers side by side between a single SSR.
GENERAL NOTES