THERMAL DERATE INFORMATION
(iii) SSR metal base plate acting as heat sink, it must be exposed to free ambient air.
0
10
20
30
40
20 30 40 50 60 70 80 90 100
2°C/W
3°C/W
5°C/W
DC100D40
Load Current (Amps)
Ambient Temperature °C
0
5
10
15
20
20 30 40 50 60 70 80 90 100
5°C/W
No Heat Sink (iii)
DC100D20
Load Current (Amps)
Ambient Temperature °C
0
2
4
6
8
10
20 30 40 50 60 70 80 90 100
5°C/W
No Heat Sink (iii)
DC100D10
Load Current (Amps)
Ambient Temperature °C
0
20
40
60
20 30 40 50 60 70 80 90 100
Load Current (Amps)
Ambient Temperature °C
1°C/W
2°C/W
5°C/W
DC100D60
0
20
40
60
80
Load Current (Amps)
Ambient Temperature °C
20 30 40 50 60 70 80 90 100
0.5°C/W
1.5°C/W
3°C/W
5°C/W
DC100D80
Load Current (Amps)
Ambient Temperature °C
0
20
40
60
80
100
20 30 40 50 60 70 80 90 100
DC100D100
0.5°C/W
1.5°C/W
3°C/W
5°C/W