Datasheet

THERMAL DERATE INFORMATION
AGENCY APPROVALS
Designed in accordance with the requirements of IEC 62314
EN60950 : Meets the requirements of sections1.5: 1,7: 2.9: 2.10.5.3: 4.2: 4.5: 4.7:
IEC 61000-4-2 : Electrostatic Discharge – Level 3 (Level 4 with “P” option)
IEC 61000-4-3 : Radiated Electromagnetic Noise – Level 3
IEC 61000-4-4 : Electrically Fast Transients – Level 3 (Level 4 with “P” option)
IEC 61000-4-5 : Electrical Surges – Level 3
IEC 61000-4-6 : Conducted Electromagnetic Noise – Level 3
E79183 1405925
Rev. 032013
Rugghölzli 2
CH - 5453 Busslingen
Tel. +41 (0)56 222 38 18
Fax +41 (0)56 222 10 12
mailbox@sentronic.com
www.sentronic.com
Produkte, Support und Service
SEN
TRONIC
AG