Datasheet

Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
Datasheet
Panel Mount
INPUT SPECIFICATIONS
(1)
Description 8413x750
Control Voltage Range 3-32 VDC
Maximum Reverse Voltage -32 VDC
Minimum Turn-On Voltage 3 VDC
Must Turn-Off Voltage 1 VDC
Minimum Input Current (for on-state) 9 mA
Maximum Input Current [mA] 14.5 mA
Nominal Input Impedance [Ohms] Current Regulated
Maximum Turn-On Time [μsec] 100
Maximum Turn-Off Time [μsec] 200
8413x8xx
3.5-32 VDC
-32 VDC
3.5 VDC
(4)
1 VDC
11 mA
15 mA
75
50
GENERAL SPECIFICATIONS
(1)
ParametersDescription
Dielectric Strength, Input to Output (50/60Hz) 3700 Vrms
Dielectric Strength, Input/Output to Ground (50/60Hz) 2500 Vrms
Minimum Insulation Resistance (@ 500 VDC)
10
9
Ohms
Maximum Capacitance, Input/Output 8 pF
Ambient Operating Temperature Range (5) -40 to 100 °C
Ambient Storage Temperature Range -40 to 100 °C
Weight (typical) 2.46 oz (70 g)
Housing Material UL94 V-0
Baseplate Material Aluminum
Input Terminal Screw Torque Range (in-lb/Nm) 13-15 /1.5-1.7
Load Terminal Screw Torque Range (in-lb/Nm) 18-20 / 2-2.2
SSR Mounting Screw Torque Range (in-lb/Nm) 18-20 / 2-2.2
LED Input Status Indicator Green
MTBF (Mean Time Between Failures) at 40°C ambient temperature (6)
11,641,553 hours (1,328 years)
MTBF (Mean Time Between Failures) at 60°C ambient temperature (6)
7,210,376 hours (823 years)
Humidity per IEC60068-2-78 93% non-condensing
GENERAL NOTES
For additional information or specific questions, contact Crydom Technical Support.
(1)
All parameters at 25°C unless otherwise specified.
(2) Heat sinking required, see derating curves.
(3) 8 VDC Minimum control voltage. Resistive loads only. Consider switching losses; at maximum frequency reduce to 75% output current.
(4) Increase minimum voltage by 1V for operations from -20 to -40°C.
(5) Maximum ambient temperature for 8413x750 is 80°C, decrease maximun control voltage 1.35V/°C above 80°C ambient temperature.
(6) All parameters at 50% power rating and 100% duty cycle (contact Crydom tech support for detailed report).