Product guide
SCADA 3000
& Accessories
SCADA 3000
& Accessories
40 WWW.SENSAPHONE.COM
WWW.SENSAPHONE.COM
41
SCADA 3000 Modules
SENSAPHONE
Product Option
Description
Specifications Specifications
Description
Number of Inputs: 4
Compatible with:
Dry contact switches, relays,
solid state switches, and
digital 5V logic
Input Sense Voltage:
5VDC@2mA
Pulse Counting Range:
0 to 10,000 pulses per second
Operating Temperature:
0° to 70°C (32° to 158°F)
Humidity
5 to 90% non-condensing
Dimensions:
4.2” x 6.3” x 1.2”
106mm x 160mm x 30mm
Weight:
.75lbs (.34kg)
Enclosure:
Aluminum housing with
integral mounting flanges for
wall or panel installation.
The SCADA 3000 Pulse
Count Module features
four totalizing pulse count
channels and four virtual
channels that can be
programmed to calculate
various rates or to display
count overflow. The four
pulse count channels are
capable of counting pulses
at a rate of up to 10,000
pulses per second (10KHz).
Each channel will totalize
pulses up to one million and then reset to zero. The four virtual
channels can be programmed to calculate the pulse as either
pulses per second, pulses per minute or pulses per hour.
Pulse Count Module
Universal Input Module . . . . . . . . . .FGD-3010
8 Universal Inputs
Configurable as:
NO/NC Dry Contact, Run
Time, 0-5V Analog Voltage,
4-20mA Current Loop, 10K
Thermistor
10K Thermistor Range
-100° to 300°F
-75° to 150°C
Operating Temperature:
0° to 70°C
32° to 158°F
24V Output Current:
160mA max
Power Requirements:
10-15VDC 100mA (typical)
/ 420mA(max)
Dimensions:
6.1” x 6.3” x 1.2”
156mm x 160mm x 30mm
Weight:
.75lbs (.34kg)
Enclosure:
Aluminum housing with
integral mounting flanges for
wall or panel installation.
The SCADA
3000 Universal
Input Module
is an optional
component for use
with the SCADA
3000 system. The
input channels are
identical to those
included on the
SCADA 3000 main
unit. The Universal
Input Module features eight channels that can be configured to
interface with several different types of sensors and transducers,
including: Normally Open/Normally Closed dry contacts, digital
logic, run time accumulation, 0–5V analog, 4–20mA analog and
10K thermistor (ºC & ºF).
Universal Input Module
Pulse Count Module . . . . . . . . . . . . . FGD-3020
SCADA 3000 Modules
Specifications
SENSAPHONE
Product Option
Specifications
Number of Outputs: 4
Output Current (sourcing):
0-20mA
Output Types:
4-20mA, 0-20mA, 0-10V
Power Requirements:
10-15VDC 260mA (max),
3.9W
Operating Temperature:
0° to 70°C
32° to 158°F
Humidity:
5 to 90% non-condensing
Dimensions:
4.2” x 6.3” x 1.2”
107mm x 160mm x 30mm
Weight:
.75lbs
Enclosure:
Aluminum housing with
integral mounting flanges for
wall or panel installation.
The SCADA 3000
Analog Output Module
features four analog
output signals that can be
configured as 4–20mA,
0–20mA, or 0–10V.
The outputs can be used
to control equipment,
drive digital displays, or
provide information to
other computer devices.
The individual outputs
are capable of driving
up to 1000 Ohms. They
may be controlled
automatically via a ladder program or C-program. The module
also features a microprocessor watchdog circuit to maintain
system reliability. LED indicators are provided to show system
power and module operation via a blinking pulse LED.
Analog Output Module
Relay Output Module . . . . . . . . . . . FGD-3040
Latching Relay Outputs: 8
Rated Load (resistive):
2A 125VAC, 2A 30VDC
Rated Load (inductive):
1A 125VAC, 1A 30VDC
Max Operating Voltage:
125VAC, 125VDC
Minimum Permissable
Load:
10mA, 5VDC
Max Switching Capacity
(resistive):
125VA, 60W
Max Switching Capacity
(inductive):
125VA, 30W
Power Requirements:
10-15VDC 80mA, 1.2W
The SCADA 3000
Relay Output Module
is an optional
component for use
with the SCADA 3000
system. The output
channels are identical
to those included on
the SCADA 3000
main unit. The Relay
Output Module features
eight latching relay
outputs that can be used to switch equipment on and off.
The relays are rated at 2 Amps at 125VAC and have integral
contact protection. They may be controlled manually or
automatically via a ladder program or C-program. In addition,
a microprocessor watchdog circuit is integrated to maintain
system reliability. LED indicators are provided to show system
power and module operation via a blinking pulse LED.
Relay Output Module
Analog Output Module . . . . . . . .FGD-3050
Description
Description