Product guide
SCADA 3000
& Accessories
SCADA 3000
& Accessories
38 WWW.SENSAPHONE.COM
WWW.SENSAPHONE.COM
39
SENSAPHONE
Monitoring Solution
Industrial Monitoring
SENSAPHONE SCADA 3000 Features
Description
The Sensaphone SCADA is a very advanced and unique system in
the Sensaphone industrial line. Flexible communication options allow
the system to communicate with a host PC through standard RS232
serial, standard data radio, ordinary telephone lines or a mix of both.
The SCADA 3000 will call you using your own pre-recorded voice
messages to alert you to the situation, or contact you via fax, numeric /
alphanumeric pager, e-mail, or even by creating web pages of data. Each
Sensaphone SCADA 3000 includes 16 universal inputs and eight relay
outputs. But the system can grow as the needs of your application grow—
expanding to 144 I/O points by adding expansion modules.
Standard with each Sensaphone SCADA 3000 is a powerful 32-bit
software system complete with a real-time screen builder, program
editors, alarm functions and a communications manager. Through this
versatile Windows®-compatible software, you can program units,
develop ladder and C-programs,
retrieve data, analyze event logs
and print a variety of reports.
The SCADA 3000 offers the
widest variety of methods for
viewing data, reports and alarm information. The interface offers
maximum flexibility: Receive customized alarm messages that you
record; receive polled data reports; view changing data live on a real-
time screen; or even have the SCADA 3000 prepare and upload pages
of data to your internet or intranet web site.
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Part Number
Sensaphone SCADA 3000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FGD-3000
Sensaphone SCADA 3000 Hard Wired Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FGD-3100
Sensaphone SCADA 3000 Plug in Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FGD-3110
Sensaphone SCADA 3000 5Ah Battery Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FGD-3200
Sensaphone SCADA 3000 18Ah Battery Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FGD-3210
Sensaphone SCADA 3000 Spare Fuse Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FGD-3220
4-Conductor RS-485 Cable for Module Expansion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FGD-0051
Ethernet Kit for SCADA 3000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FGD-0300
16 Universal Inputs
8 Relay Outputs
I/O Expansion
up to 144 points
RS–485
Data Logger
Ladder Logic Control
C Program Control
RS–232
Local PC
Optional
Ethernet
Adapter
Networked PC
Ethernet
Pager/Text/Fax
Voice Phone Calls
Voice Call In
Modem
Remote PC
Phone Line
Public
Phone
Network
Inputs:
• 16 standard universal inputs
support:
Normally Open or Normally
Closed contacts
4–20mA transducers
Temperature sensors: -85°F
to 300°F
8 Outputs:
• Latching 2 amp relays
• LED status indication
2 RS232 ports:
• Local programming
• Data radio communications
• RJ11 Phone interface for optional
voice and data communications
• RJ11 Line Seizure jack
LCD:
• 4 by 20 character scrolling
display
• User customized content for local
viewing
Data Logging:
• Fully user programmable built-
in data storage for logging I/O
points or calculated variables
Event Logging:
• Internal tracking of all significant
alarms and events
Ladder Logic
Programming:
• Standard ladder programming
included for true PLC type
control
• Visual ladder editor is part of free
software package
C-Programming:
• Built-in C-compiler, allowing
complex calculations C-program
is capable of running on a
schedule, independent of ladder
program
PID:
• Eight PID loops are built-into
internal programming
• Any I/O points are selectable to
function in PID calculations
Communications:
• Phone modem – allows modem,
fax, and pager communications
• Voice module – allows custom
voice messages over standard
phone lines
Options:
• Input/Output Options (expandable
to 144 points)
• Universal inputs (same as 16
already built-in)
• High Speed pulse count inputs
• Relay Outputs
• Analog Outputs (4–20mA)
Power Supply Options:
• Hard wired power supply for 110
or 220 VAC operation
• Plug-in power supply – for 110 or
220 VAC operation
• Standard battery backup
• Extended battery backup
Software:
Provides the capability to program
units, develop ladder programs,
develop C-programs, retrieve and
analyze the data and event loggers
plus print all necessary reports.
• Automatically polls for data using
phone lines or radio modems.
• Performs all standard SCADA
functions with customized
on-screen graphics
Why choose the
scada 3
000?
• 16 inputs and 8 outputs
plus expansion.
• Programmable control using
Ladder or C
• Uses standard phone line
• Free HMI software
With our SCADA system, everything comes in one
comprehensive package for all the sophisticated
control and alarm capability you will ever need.