Instructions / Assembly

84
SENSAPHONE 1800 User’s Manual
APPenDIX B: RePLACInG
tHe BACK-UP BAtteRY
The back-up battery will provide about 3–5 years of service life depending
on usage and temperature. After 5 years (or when back-up time is insuffi-
cient) the battery should be replaced. Replacement batteries can be ordered
from Sensaphone (Part number BAT-0006). To replace the battery, follow
the instructions below:
When removing and replacing the battery, be careful not to short out
the battery terminals on the bracket or back panel. A large spark and/or
battery damage could result.
1. Turn the power switch off and unplug the power transformer.
2. Loosen the compression wiring connectors and allow 6-10” of cable
slack to come into the enclosure. This will make it easier to turn the
panel over.
3. Remove the four corner screws securing the keypad/pcb panel and turn
the panel over.
4. Remove the connectors from the battery by carefully pulling and wig-
gling the connectors from the battery tabs.
5. Remove the screws holding the battery bracket and remove the bracket.
6. Dispose/Recycle the old battery following local disposal regulations for
lead batteries.
7. Attach the battery connector at the end of the BLACK wire to the
-(negative) terminal of the new battery.
8. Attach the battery connector at the end of the RED wire to the +(posi-
tive) terminal of the new battery.
9. Insert the new replacement battery into the slot and replace the brack-
et. Secure the bracket with the two screws.
10. Place the main panel over the four metal stand-offs and reattach the
four corner screws.
11. Readjust the cables through the compression connectors and secure
the fittings.
12. Plug the power transformer into the outlet and turn on the power
switch.