User Guide
2023-01 | v2.0
Planning guide for system integrators
TeamConnect Ceiling 2
Obstacles in the room
Some rooms are equipped with technologies that cause additional noise or interference. Such sources
of interference could be an air conditioner, a coffee machine, or the fan noise from a ceiling-mounted
projector that is mounted near the ceiling microphone.
To prevent noise from these sources from being transmitted through the ceiling microphone array,
you can define up to five Exclusion Zones in the Control Cockpit software. The Exclusion Zones
enable you to eliminate unwanted sources of constant noise in order to optimize the audio experi-
ence. Obstacles may be located at the edges of the room or on the ceiling.
Obstacles on walls or at the edges
If the obstacles are located on walls or at the
edges of a room, the TCC2 should preferably
be installed in or suspended from the ceiling.
You can then use the Control Cockpit software
to identify the obstacles and exclude them
from the active detection radius based on their
vertical and horizontal position in the room.
Up to five Exclusion Zones can be created and
activated simultaneously.
Example
If there is a speaker mounted on the wall, the
TCC2 will automatically track to that audio
source. The yellow dot and conical beam in the
3D Overall View will show the exact position
of the audio source.
This automatic noise detection enables you
to precisely define an Exclusion Zone for this
area (e.g. the area around a screen with audio
output).
Once the defined Exclusion Zone is activated,
incoming signals from this area are no longer
picked up.
Fig. 16: Exclusion Zone of an audio device
Fig. 17: Simulated view with activated Exclusion Zone