User Guide
2023-01 | v2.0
Planning guide for system integrators
TeamConnect Ceiling 2
Positioning in the room
For maximum coverage in the room, the TCC2 should be positioned so that it covers the entire area
to be detected from a central position. In some cases the preferred central position in the room’s
ceiling may be occupied by lights, built-in air conditioning units or other devices. As long as the
minimum distances are observed and the coverage radius is taken into account, the TCC2 can also
be positioned in a non-central location.
Example:
5 m (16 ft)
10 m (33 ft)
10 m (33 ft)
10 m (33 ft)
10 m (33 ft)
The preferred position in the center of the
ceiling is blocked by other installations and
cannot be used for the TCC2.
The TCC2 is installed in a non-central position
that still ensures full coverage of the intended
area.
Extending the coverage radius
If the coverage of a single TCC2 is not sufficient for the required area, you can extend the coverage
radius with additional units. Note that the distance between the TCC2 devices should not exceed 7
to 8 m (23 to 26 ft).
Example:
The intended coverage cannot be achieved
with a single TCC2.
An additional TCC2 makes it possible to cover
the required area.