Instruction manual

Mounting and installing the products
22 | SpeechLine IS microphone series
Mounting microphones to the ceiling
Some microphones of the IS series can also be mounted to a ceiling panel
or wooden board of a suspended ceiling.
A) Mounting the MEB 102boundary layer to the ceiling
Once you have chosen a position fo
r the product (see page 16):
Remove the ceiling panel or the wooden boar
d and place it on a surface
that is suitable for drilling.
Drill a hole with a diameter of 25 mm through the ceiling panel or
wo
oden board (plate thickness 10 mm - 65 mm).
Slide the first rubber ring over the
threaded bolt of the microphone
button and then insert the microphone into the drilled hole.
Slide the second rubber ring over the threaded bolt and tighten the hex
nut.
Connect a suitable cable (see page 26), lay the cable
and remount the
ceiling panel or wooden board.
MEG 14-40L
MZH 30xx-L
MZT 30
MZS 31
ME 34|35|36
MZH 30
MZC 30
A
C
B
XLR-3
MZT 30
MZH
3015w
MZT 30
MZC 30
MZH 30
ME 34
ME 35
ME 36
+
+++
MEB 102
25 mm
10 mm –
65 mm