Configuring the conference system via the central unit
36
Remedy Perform a manual self-test (see page 40).
The display can change as follows:
The structural change icon disappears: The structural
change has been detected, there are no errors.
The structural change icon is still displayed: Follow the
steps below.
If, after performing the self-test, the structural change icon is still
displayed:
Reset the error counter (“Break Counter”) (see page 40).
Change to the “Bus Statistics” menu item (see page 39) and
check the digit behind “Break Counter”.
Carefully move the conference units and systems cables and
check if the
digit behin
d “Break Counter” is increased.
If the digit is increased, check the correspon
ding plug connec-
tions or replace the corresponding c
onference units and system
cables.
If the error still occurs:
Follow the steps described in the “System Load” menu item (see
page 38).
Perform a manual self-test (see page 40).
Display
The warning triangle and the
structural change icon are
displayed.
Error and
remedy
Change in the number of conference units during the self-test:
After switch-on, an automatic self-test is
performed which simu-
lates a running conference with all the conference units connected.
If a failure of conference units occurs, the above ment
ioned error
icons appear.
A failure of conference units can be caused by undervoltages or
o
v
ercurrents:
Follow the steps described in the “System Load” menu item
(see page 38
).
Perform a manual self-test (see page 40).