User guide

23
Monitoring devices
Observing and evaluating the field strength display
Observing the field strength and recognizing deviations
The current values of the field strength are displayed as bars in the panels.
The horizontal yellow line indicates the squelch level.
If the field strength drops below the squelch level, the bar displayed
appears in red and the corresponding receiver is silenced.
If the field strength is above the squelch level, the bar displayed appears
in green.
To change the value of the squelch level:
Click on the panel using the right mouse button.
A contextual menu appears.
Click on “Properties...”.
The “Properties” window opens.
Select the “Squelch” line and confirm with “Set”.
A new window opens.
Click on the arrow next to the list field and select a threshold for the
squelch level.
Confirm with “OK”.
The window closes and the set threshold value appears in the
“Properties” window.
Close the “Properties” window.
The yellow line for the squelch level in the panel readjusts accordingly.
Retrieving messages from the receivers
The “WSM” allows all connected receivers to be monitored during
operation. Notifications and messages about problems appear in the
display field of the “Messages” system window. In addition, the “WSM”
identifies priorities regarding the messages.
The retrieve the messages:
Click on the “Messages” register in the system window.
If the system window is not visible:
Click on “View” > “System Window” in the menu bar.
The system window opens.
Click on the symbol to maximize the window.
Low: Low threshold value
Mid: Moderate threshold value
High: High threshold value