Working with panels
The panel view
Every panel displays a receiver that is connected to the NET 1.
Layout of the panel
Name of the device
The name of the device is read from the device and displayed, or, if the
device has no name, “DEVICE” is displayed together with a sequentially
assigned number. You can change the name of the devices. The name is
restricted to 10 characters.
Frequency display
The frequency of the receiver appears below its name.
Diversity channels
The currently active channel “A” or “B” is displayed in green .
Field strength display
The bar height indicates the current field strength. The horizontal yellow
line indicates the limit set for the squelch level. If the field strength is
below the limit for the squelch level, the bar appears in red and sound is
suppressed.
Modulation (Deviation)
Level indicator for the audio level at the transmitter.
Battery status
The battery symbol indicates the charge level battery/batteries. The
segments remain green until the battery is almost fully discharged. If a
critical charge level is reached, all segments start to flash in red. In addition
a message appears in the “Messages” window.
Variants 1 and 3: The modulation is shown as a bar graph.
Variant 2: The modulation is displayed in three steps, each
with a different color that corresponds to the