Microphone User Manual
Table Of Contents
- Instructions for use
- Brief description
- Connecting facilities/power supply
- Stand mounting/acceptance angles
- Application tips
- Selection of pick-up patterns
- Preattenuation / tone control
- Accessories
- Technical Data
- Nominal frequency response omnidirectional
- Nominal frequency response wide-angle cardioid
- Nominal frequency response cardioid
- Nominal frequency response supercaedioid
- Nominal frequency response figure-of-eight
- Filter effects
18
L
H
B
Preattenuation / tone control
Switch L for preattenuation
If the output level of the MKH 800 is
too high for the following mixing
console, it can be reduced in two steps:
- 6 dB
or
- 12 dB
Switch H for treble emphasis
The treble emphasis can be adjusted in
two steps. For 8 kHz the increase
amounts to:
+ 3 dB
or
+ 6 dB
Switch B for bass attenuation
The bass response can be attenuated
in two steps. For 50 Hz the attenua-
tion amounts to:
- 3 dB
or
- 6 dB