L 2015 Instructions for use 17
Safety instructions Only use the L 2015 charger for charging the BA 2015 accupack! Never try to charge other rechargeable batteries or non-rechargeable batteries! Keep liquids and small parts away from the unit! Never use the unit in humid environments! Keep the accupack contacts and the contacts of the charger clean! For cleaning, disconnect the unit from the mains! Use a brush or a slightly damp cloth for cleaning the unit.
The L 2015 quick charger The L 2015 quick charger must only be used for automatically charging BA 2015 accupacks – individual rechargeable battery cells or primary cells cannot be charged! The BA 2015 accupack is suitable for units of the Sennheiser ew G2 series and the System 2015. The bodypack receivers (EK) and transmitters (SK) of the Sennheiser ew 300 G2 and ew 500 G2 series and the System 2015 have special charging contacts, i.e. these units can be charged with the accupack inserted.
! Up to three chargers can be cascaded together to form a larger charging station which can be powered by a common mains unit. Delivery includes ! L 2015 quick charger ! Instructions for use Suitable mains units are available as accessories (see ”Accessories“ on page 29).
Operating controls Red LED CHARGE/ERROR (2 x) Green LED READY (2 x) Charging compartment for BA 2015 accupack (2 x) Charging compartment for SK/EK of the ew 300 G2 or ew 500 G2 series and the System 2015 (2 x) Air vents DC socket for connection of mains unit Guiding slot with internal rail (2 x) 21
LED indications Each charging compartment has two LEDs which indicate the following operating states: No LED lit: The charging compartment is ready for operation (provided that the charger is connected to the mains), no accupack is identified. All LEDs briefly light The charger has been connected to up one after the the mains and is carrying out a self other: test. Red LED lit: The accupack is being charged. Red LED flashing: A problem has occured (see ”If problems occur...“ on page 27).
Cascading several chargers 왘 Make sure that the charger is disconnected from the mains. 왘 Unscrew the two screws at the right bottom side of the charger. 왘 Slide the two rails out of the guiding slots and screw them tight using the two screws . 왘 Unscrew the two screws at the left bottom side of the second charger. 왘 Slide the second charger onto the rails of the first charger and screw the rails tight using the two screws .
Setting up the charger The charger has four plastic feet to ensure that it cannot slip on the surface on which it is placed. Attention! Some furniture surfaces have been treated with varnish, polish or synthetics which might cause stains when they come into contact with other synthetics. Despite a thorough testing of the synthetics used by us, we cannot rule out the possibility of staining.
Charging the BA 2015 accupack 왘 Insert the accupack into one of the two charging compartments as shown. The red LED at the occupied charging compartment lights up. Charging a completely discharged accupack takes approx. 2½ hours at room temperature. It is normal for the accupacks to get warm during charging.
왘 After the accupack has been fully charged, the green LED lights up. Note: For charging, the accupacks can remain in the bodyback transmitter (SK) or receiver (EK). Place the unit with the accupack inserted into the charging compartment as shown. When placed into the charger, the EK/SK automatically switches off (except for EK 300 IEM).
If problems occur... If a red LED starts flashing, one of the following errors has occurred at the corresponding charging compartment: ! No contact with the accupack (contacts are dirty or accupack is not inserted correctly): Clean the contacts or insert the accupack correctly. ! Accupack is defective (overaged or defective rechargeable battery cells): Replace the accupack. ! Accupack temperature is too low or too high: Always charge the accupack at room temperature.
Specifications Input voltage: 12 V DC via hollow jack socket Hollow jack: Input current: max. 750 mA Charging voltage: 2 x 2.9 V Charging current: 2 x 700 mA Charging principle: –∆U method Deep discharge recovery charge Trickle charge Accupack temperature monitoring Over/undercharge detection Charging time limit (max. 6 h) BA 2015 battery type: 2 x 1.2 V 1500 mAh, NiMH Charging time: approx. 2.
Accessories BA 2015 Accupack for powering units of the Sennheiser ew G2 series and the System 2015 NT 1 Mains unit for powering a single L 2015 charger NT 3 Mains unit for powering up to three cascaded L 2015 chargers 29
ENGLISH The guarantee period for this Sennheiser product is 24 months from the date of purchase. Excluded are accessory items, rechargeable or disposable batteries that are delivered with the product; due to their characteristics these products have a shorter service life that is principally dependent on the individual frequency of use. The guarantee period starts from the date of original purchase. For this reason, we recommend that the sales receipt be retained as proof of purchase.
Konformitätserklärung Sennheiser electronic GmbH & Co. KG erklären, dass dieses Gerät die anwendbaren CE-Normen und Vorschriften erfüllt. Approval Sennheiser electronic GmbH & Co. KG declare that this device is in compliance with the applicable CE standards and regulations. Certification Sennheiser electronic GmbH & Co. KG déclarons que cet appareil est en conformité avec les normes CE. Certificazione Sennheiser electronic GmbH & Co.
Sennheiser electronic GmbH & Co. KG 30900 Wedemark, Germany Phone +49 (5130) 600 0 Fax +49 (5130) 600 300 www.sennheiser.com Printed in Germany Publ.