Putting the conference system into operation
80 | ADN Digital Conference System
Using the media control system
To integrate the conference system into a media control system, make sure that
the following requirements are met:
The media control system is capable of sending and receiving ASCII control
commands.
The conference system and the media control system are interconnected via an
Ethernet network.
The network communication is not blocked (for example by a firewall).
Connecting the media control system
To connect the central unit to a media control system:
Use a network cable (Cat5) to connect the Ethernet socket of the central unit
to the network interface of your media control system.
Connecting the media control system to the central un
it
To enable communication between the central unit and the media control system:
Make sure that the network communication between the central unit and
the
media control system is not blocked by a proxy server and/or a firewall.
Port 53252 is used for communication.
Connect the media control system to the centr
al
unit via the IP address of the
central unit. The central unit serves as a socket server and communicates with
the media control system via TCP and port 53252. For more information on set-
ting the IP address of the central unit, refer to the following chapters:
“Adjusting network settings – “Network” submenu” on page 113
“Adjusting the network settings” on page 131
“Adjusting network settings” on page 153
Programming the media control system
Depending on the media control system used,
y
ou can individually program the
graphical interface and the operating sequences and adapt them to your require-
ments.
You can find all information on the control commands and output instructions of
the conference system for programming the media control system in the PDF doc-
ument “ADN_MediaCtrl_Protocol.pdf” included on the DVD-ROM (supplied with
the
central unit) or at www.sennheiser.com.
For more questions on the integration of the ADN conference system into a media
control system, contact your Sennheiser partner.
Media
control
system
IN –– AUDIO –– OUT
PORT II PORT I
100-240V~
50/60Hz 240W
2x 52.8V 1.75A
B
You can also connect the media control system and the central unit using a
switch or similar.