ADN System Instruction Manual

Table Of Contents
ADN Digital Conference System | 221
Using the “Conference Manager” software
“Warning“
Column “Description“ “Location“ Meaning
Available USB device
space below 500 MB
[CU Main
######]
Available memory space on the USB
mass storage device < 500 MB
Bus Error (###
Frames)
[CU Main
######]
Data transmission error; number of lost
data frames
More than
400 conference units
(x) connected!
[CU Main
######]
More than 400 conference units are
connected. System stability is no longer
guaranteed! A system error can occur.
Chairperson unit S/N:
###### at pos.###
NOT INITIALIZED
[CU Main
######]
The chairperson unit is not initialized
More than 15 ADN PS
devices (x) connected!
[CU Main
######]
The maximum number of connected
ADN PS power supplies has been
exceeded.
Conference Reinit due
to inconsistent
topology
[CU Main
######]
Re-initialization due to inconsistent set
up of the conference system
Device Temperature
Overheat/OK
[CU Main
######]/
[PS ######]
Temperature of the central unit/power
supply is within the permissible range
(“ok”)/too high (“overheat”)
Fan status:
Fan1=ALERT/OK;
Fan2=ALERT/OK
[CU Main
######]/
[PS ######]
Fan 1/2 of the central unit/power
supply is in operation (“ok”)/has failed
(“ALERT”)
High Current status:
(Port1=ALERT/OK,
Port2=ALERT/OK)
[CU Main
######]/
[PS ######]
Current at PORT I/PORT II of the central
unit/power supply is within the permis-
sible range (“ok”)/too high (“ALERT”)
Low Voltage Alert at
Unit Pos.###
[Unit at
Pos.###]
Voltage required for powering the
conference units is too low
More than max
number (150) of
wireless conference
units tried to register
to the system
[CU Main
######]
The maximum number of wireless
conference units has been exceeded.
Microphone Limit
changed to ## due to
number of chair-
person units
[CU Main
######]
Microphone limit has been changed due
to changed number of chairperson units
Microphone limit
readjusted to max
possible value=##
[CU Main
######]
Microphone limit has been adjusted to
the maximum possible value.
More than 4 ADN-
W AM devices (x)
connected!
[CU Main
######]
The maximum number of antenna
modules (4 per central unit) has been
exceeded.
Premonition Time
readjusted to ##s
due to Talk Time Limit
conflict
[CU Main
######]
Advance warning time has been
adjusted due to conflicts with the
speaking time limit
Short-Circuit status:
(Port1=ALERT/OK,
Port2=ALERT/OK)
[CU Main
######]/
[PS ######]
Short-circuit at PORT I/PORT II of the
central unit/power supply (“ALERT”)/no
short-circuit at PORT I/PORT II of the
central unit/power supply (“ok”)