ADN System Instruction Manual

Table Of Contents
ADN Digital Conference System | 217
Using the “Conference Manager” software
Recording a conference – “Conference Recording”
In “Live” operating mode, the ADN CU1 central unit allows you to record the floor
channel and the channels of all active conference units as audio files on a USB mass
storage device. Information on the requirements and recording possibilities can be
found in the chapter “Recording a conference” on page 122.
Starting an audio recording Make sure that the USB mass storage device
is correctly connected to the
ADN CU1 central unit (see page 75).
In the menu bar, click “Settings” > “Conference Recording”.
The “Conference Recording” window appears.
Click “Record”.
The recording is
started. The “Record” button is grayed out and the “Stop” but-
to
n and the recording icon are active. The icon is displayed on the CU1 dis-
play panel.
Monitoring an audio recording The “Event Log” function of the “Conference Managers” software logs all informa-
tion on the audio recording (see page 219).
In “Live” operating mode, the “Recording” box shows whether or not the confer-
ence is reco
rded and provides information on the available memory space on the
USB mass storage device (see page 216).
The CU1 display panel displays the status of the audio recording:
CAUTION
Loss of an audio recording!
If you disc
onnect the USB mass storage device from the central unit during an audio
recording, the audio recording can be rendered unusable due to faulty data.
Stop the audio recording (see page 218) an
d make sure that the icon is no
longer displayed in the CU1 display panel before disconnecting the USB mass
storage device from the central unit.
If you exit the “Live” operating mode, the audio recording is not stopped.
O
Direct Access 30 D1/C1
22
O
icon
Meaning
Audio recording in progress
flashing
Memory space < 500 MB
Depending on the number of channels recorded, the memory
capacity will suffice for approx. 15 minutes of recording. Stop
the audio recording (see page 218) and, if necessary, change
the USB mass storage device.
After finishing the audio recording, data is still written to the
mass storage device.
The central
unit’s display
panel lights up
red
An error occurred during recording. The recording was inter-
rupted.
O