Instruction manual Set 880
Table Of Contents
- Important safety instructions
- Package contents
- Product overview
- Putting the Set 880 into operation
- Setting up the transmitter
- Connecting the transmitter to audio sources
- Connecting the transmitter to the power supply system
- Charging the stethoset receiver’s rechargeable battery
- Displaying the remaining operating time of the rechargeable battery
- Using the charging reminder function
- Selecting and replacing the ear pads
- Using the Set 880
- Cleaning and maintaining the Set 880
- Using additional functions
- If a problem occurs ...
- Specifications
- Manufacturer Declarations
- Warranty
- In compliance with the following requirements
- Statements regarding FCC and Industry Canada
- RF Radiation Exposure Information
- Information sur l’exposition aux rayonnements radio fréquence (RF)
- Cet émetteur ne doit pas être positionné à proximité d‘une autre antenne ou d‘un autre émetteur, ni utilisé avec une autre antenne ou un autre émetteur.
- Trademarks
Using additional functions
36 | Set 880
Battery status display
This setting is saved on the transmitter, independent of the ste-
thoset receiver you are using.
To change the battery status display:
E Make sure that the protected settings mode is activated (see
page 35).
E Press the Balance button L.
* factory setting
E Save the setting by disconnecting the transmitter from the
power supply system (see page 35).
Charging reminder function
This setting is saved on the transmitter, independent of the ste-
thoset receiver you are using.
To activate or deactivate the function:
E Make sure that the protected settings mode is activated (see
page 35).
E Press the Balance button R.
* factory setting
E Save the setting by disconnecting the transmitter from the
power supply system (see page 35).
Status and display of the
Battery
LED
Function/behavior
permanently activated
(operation and charging)*
1
st
LED segment lit
The current charge status is
permanently displayed during
charging. The remaining charge status
is permanently displayed during
operation.
activated for 30 seconds
(operation and charging)
1
st
LED segment off
The current charge status is displayed
for 30 seconds during charging. Then
all LEDs go off. The charging process is
continued. The remaining charge
status is displayed for 30 seconds
during operation. The battery status
display then goes off.
Status and display of
the charging reminder
function
Function/behavior
activated*
5
th
LED segment lit
When you switch the stethoset
receiver off and the transmitter
switches to standby mode, the
battery status display will flash for
10 minutes to remind you to charge
the stethoset receiver.
deactivated
5
th
LED segment off
After switching the wireless
headphone system off, all LEDs
remain off.