User's Manual

Prepared by KM 11/2015 7 Patent pending
14407 Coil Plus Dr, Unit A | Plaineld, IL 60544
www.sennco.com | techsupport@sennco.com
815.577.3400 | Toll free 866.736.6261
Mon - Fri 9AM - 5PM CST
Teach keys
1. Insert a known DaKey
2. Press and hold buon
Congure system
3. Release buon when
LCD reads “Release to congure”
DaKey
stays
in
4. Watch LCD
LCD reads “Conguring devices 001” with count increasing as
devices are congured.
5. Remove DaKey when prompted
LCD reads “Congured. Devices found (quanty of devices).
Remove key.”
6. If the number of devices found diers from actual check all
components and repeat conguraon.
1. Gather all DaKeys
2. Insert DaKey
3. LCD reads “Key learned
4. Remove DaKey and insert next within 5 seconds (Reinsert a
“taught” DaKey again if 5 second window is missed.)
5. Repeat for up to 10 DaKeys
Main alarm
DaKey