Instruction manual
SENKO cookers 2P extra rustik and glass – Instruction manual 40
10. TECHNICAL DATA
SENKO cooker
C-20 2P
C-30 2P
Nominal heat output, kW
25
35
Boiler, kW
16
20
Room, kW
9
15
Amount of water in boiler, L
20
28
Operating pressure (max), bar
3
Operating temperature, °C
85
Width, mm
1400
Depth, mm
680
815
Height, mm
850/1255
Weight, kg
450
520
Firebox opening (W × H), mm
200×260
Firebox (W × D), mm
275×430
275×570
Firebox volume, dm
3
62,08
82,29
Fuel consumption, kg/h
9
10
Height of grate lifting, mm
175
165
Cooking plate (W × D), mm
595×465
595×595
Cooking plate area, m
2
0,276
0,354
Oven (width), mm
330
Oven (height), mm
220
Oven (depth), mm
440
550
Ash pan, L
7,5
10,5
Fuel box, L
31,6
Flue gases exhaust, mm
150
Flue gas temperature, °C
250
270
Required flue draught, Pa
12
16
CO in flue gases at 13% O
2
, %
0,5
0,56
Flue gas mass flow rate, g/s
17
33,6
Efficiency, %
75
75,5
Regulation
Primary air
automatic
Secondary air
Manufactured in accordance with EN norm
EN 12815
- technical specification apply to wood and wooden briquettes used as fuel
- technical specifications are indicative and may vary as such. The manufacturer withholds the
right to change any technical specification to further improve the products