Instruction manual

SENKO cookers 2P extra rustik and glass Instruction manual 27
primary air
connection
point (30) on
the cooker rear
end
There is a rectangular connection point for the intake of external
primary air on the cooker rear side, onto which a rectangular pipe (30),
dimensions 150 x 80 mm, can be connected.
If necessary, the rectangular cross-section may be reduced and turned
into a round opening (minimum diameter 100 mm). The connecting pipe or
the reduction must be made out of non-flammable material (in accordance
with DIN 4102-B1).
SECONDARY AIR
Secondary air is the air that flows into the firebox to facilitate
maximum combustion, reducing harmful substances to ashes and
discharging flue gas with low capacity for pollution into the chimney.
Secondary air regulator (11) is placed on the cooker front side under
the lid, between upper and lower door.
The regulator is factory set for wood and wood briquettes as fuel. If
you use some other fuel (e.g. coal), the regulator must be adjusted
manually.
figure 16