Specifications
DOOR SENSOR
DESCRIPTION SENSOR PREPARATION
1. Clean the door/wall surface.
2. Remove the slice at the boom
of the sensor to acvate the
detector. This will start the sensor
by acvang baeries already
installed.
KRG door sensor will detect every
door opening and closing.
It is composed of 2 parts : one sensor
and one magnet.
It is an advanced magnec contact
sensor with integrated sigfox
transceiver designed to be a fully
supervised low-current device.
Double-sided
tape
Slice
1. Double-sided tapes are given
to sck the sensor in the proper
posion on the door.
2. Put the sensor on the doorframe
and the magnet on the door.
Make sure the LINE on both part
matches. The two parts have to
be the closest possible without
touching each other (<20mm).
UP
DOWN
INSTALLATION
SET UP
The sensor connects automacally to
the network.
1. Red LED on the sensor ashes
every second during one minute.
2. Green or red (depending on the
conguraon) LED lights on during 5
seconds.
3. The light turns o. The conguraon
is set up.
Aer every baery replacement
or soware reset, the sensor will
perform the set up operaon.
The device shall keep at least 20cm
separated from the humans.
INSTALLATION
Specic situaons
1. You can reverse the sensor if
the door frame is too small. Put
the sensor on the door and the
magnet on the dooframe. Make
sure both parts are close and
aligned.
2. You can also put sensors on the
top of the door. Both part will be
horizontal.
DIMENSIONS
32,0 mm
115,4 mm
20,8 mm
40,4 mm
1
2
tongue
BATTERY CHANGE
When the baery is low, red LED
ashes every 10 seconds.
1. No need to remove the sensor
from the wall. Press on the front
of the sensor to open it.
2. Take out old baeries. Use the
tongue to remove baeries.
3. Install new baeries according
to polarity marking.
4. Sensor will inialize itself (see
red LED ashing for 1 minute).
SPECIFICATIONS
Sigfox Zone
RCZ2
Model Name
DS-0923ST-00
RF Specicaon
Sigfox Class 0
Magnet spec
Active range >= 20mm
LED
Dual color LED green and red
Installaon
Double-sided tapes
Baery
Alkaline battery
Baery life
>24 months
Operaon environment
-10 / +50c, 0-90% RH non-
condensing
Storage Environment
-20 / +70c, 0-90% RH non-
condensing
Specic situaons