6.1 SNMP Configuration
Description: The MRD 3187B can be controlled, configured, and monitored by SNMP via
the RJ45 Ethernet port or the RS232 port on the back of the unit. Additionally, there are
five separate SNMP traps that can be set to trigger by various error conditions.
MRD 3187B MIB Modules
The MIBs needed for SNMP configuration are included on the MRD 3187B itself. To access
and download the MIB files use the following steps:
1. Open a web browser of choice on a local computer and type the IP address of the MRD
3187B into the address bar then press enter.
2. Log into the MRD 3187B remotely.
Note: By default there is no password.
3. Click on the tab.
4. Scroll down until the “SNMP
MIB Modules” section is in view.
5. Right click on the desired MIB
module and click “Save Target
As…”
6. Now use the desired SNMP
manager to configure the MRD 3187B.
Configure SNMP Manager Addresses
Two SNMP communities exist on the MRD 3187B, a
“Read Only” Community and a “Read Write”
Community. Each one of these can be managed by
two different host addresses. To set these up use the
following steps:
1. Press the button.
2. Use the and buttons to move the cursor
to, “SNMP,” then press the button
3. Use the and buttons to move the cursor
to either, “RO Community” or “RW
Community,” then press the button.
Note: The setup instructions for the “RO Community”
and the “RW Community” are the same from
this point on.