User manual
MRD 3187B User Manual
Page 141
RDS 1
Audio 2 Setup
►SCTE35 Setup
Source ID
SCTE35
PID:0x0016 Hrtbt:10
0x0000
0x0000
SCTE35
►Mode:Manual
Heartbeat TO:10
PID 1:0x0016
SCTE35
►Mode:Auto
Heartbeat TO:10
SCTE35
Mode:Manual
Heartbeat TO:10
►PID 1:0x0016
Output
Audio 1-2
MPEG/IP 1-3
►HD Video 1-1
4.26 SCTE35 to SCTE104 Setup
Use the following steps to setup SCTE35 to SCTE104 conversion.
SCTE35 PID
There are two modes that the SCTE35 PID(s) can be entered in, Auto or Manual. In Auto
mode the unit attempts to discover the SCTE35 PID(s) as they are signaled in the stream. In
Manual mode the user must enter the PID(s) manually using each PID’s HEX PID number.
To setup the SCTE35 PID(s) use the following steps.
1. Start out at the home screen (where it shows the
TS bit rate).
2. Press the button.
3. Use the and buttons to move the cursor
to “SCTE35 Setup,” then press the button.
4. Press the button again to get to the edit
screen.
5. Use the and buttons to move the cursor
to “Mode,” then press the button.
6. Use the and buttons to select the
desired mode of operation (Auto or Manual),
then press the button to save the selection.
The following steps are only applicable to “Manual”
mode.
7. Use the and button to select “PID 1:”
then press the button.
8. Use the and arrows to select the
column to edit and use the and arrows
to enter the PID, then press the button to
save the selection.
Note: Use steps 1 and 2 above to enter the SCTE35
PIDs for fields “PID 2:” and PID 3:” if
applicable.
SCTE104 VANC Embedding
To setup the MRD 3187B to embed the SCTE104 message into the SDI VANC use the
following steps:
1. Press the button.