Instruction manual

EN - 8
SPECIFICATIONS
Main Unit
Displayed IN temperature range : -10°C to +60.0°C
Proposed operating range : 0°C to +50.0°C
Temperature resolution : 0.1°C
Remote Temperature measurement
Displayed OUT temperature range : -20.0°C to +60.0°C
Temperature resolution : 0.1°C
Indoor/Remote relative humidity measurement
Displayed Relative Humidty range : 20%RH to 99%RH
Measured temperature range : -10°C to +50.0°C
Remote Unit
Proposed operating range : -10.0°C to +50.0°C
Temperature resolution : 0.1°C
Displayed Relative Humidty range : 20%RH to 99%RH
Measured temperature range : -10°C to +50.0°C
Temperature Accuracy : +1°C(+2°C)
Humidity Accuracy : +5%RV(+8%RV)
RF Transmission Frequency : 868 MHz
Open Field RF Transmission Range : 65 meters in open space
Temperature transmission cycle time : 120 seconds
Power – Main Unit : Battery 2 x 1,5V Type AAA
(Not Included)
– Sensor : Battery 2 x1,5 Type AAA
(Not Included)
Dimensions of Main Unit : 145 x 23 x 103 mm
Weight : 190 g
Dimensions of Sensor : 54 x 25 x 105 mm
Weight : 52 g
Note:
Accuracy depend of range measurement for temperature and
humidity.
Temperature and humidity accuracy for main unit:
0°C to 40°C : +/-1°C
40°C to 50°C : +/- 2°C
40% to 80% RH : +/-5% RH
Other range : +/-8°C
Temperature and humidity accuracy for sensor:
0°C to 40°C : +/-1°C
-10°C to 0°C and 40°C to 50°C : +/-2°C
<40% to 80%< : +/-5%RH
30% to 40% 80% : +/-8%RH